Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Seismic strengthening of masonry infilled reinforced concrete frames with steel fiber reinforcement
Date
2010-12-01
Author
Sevil, T.
Canbay, Erdem
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
28
views
0
downloads
Cite This
Seismic resistance of several buildings in Turkey is deficient. Strengthening of these buildings with commonly used reinforced concrete (RC) infills requires excessive construction work. The main objective of this study is to develop a feasible, effective, and yet economical strengthening technique that does not disturb the inhabitants. The proposed method is based on application of steel fiber reinforced higher strength mortar on the plaster of masonry walls. An optimum steel fiber reinforced mortar (SFRM) was obtained in preliminary material tests. RC frames strengthened by applying the mortar onto brick masonry plastered infill walls were tested under reversed cyclic lateral loads simulating earthquake. The frames were 1/3 scale, 1 bay, and 2 story. Totally 10 frame tests were performed. Tests included 4 different reference tests, and 6 strengthened frame tests having various mortar thicknesses and steel fiber volumetric percentages. Frame having 2 percent SFRM anchored to the frame with 20 mm thickness carried approximately 2 times the lateral load of the plastered brick masonry reference frame.
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84867184251&origin=inward
https://hdl.handle.net/11511/106629
Conference Name
9th US National and 10th Canadian Conference on Earthquake Engineering 2010, Including Papers from the 4th International Tsunami Symposium
Collections
Department of Civil Engineering, Conference / Seminar
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
T. Sevil and E. Canbay, “Seismic strengthening of masonry infilled reinforced concrete frames with steel fiber reinforcement,” Toronto, Kanada, 2010, vol. 3, Accessed: 00, 2023. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84867184251&origin=inward.