Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Effects of collars on scour reduction at bridge abutments
Date
2010-12-01
Author
Göğüş, Mustafa
Dogan, Abdullah Ercument
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
23
views
1
downloads
Cite This
Bridge failures are generally resulted from scour of the bed material around bridge piers and abutments during floods. In this study, scour phenomenon around bridge abutments and collars, located at abutments as scour countermeasures, were experimentally investigated. Based on the results of 97 experiments conducted, the effect of various sizes of collars which were located around the abutments at different elevations, on the scour reduction at bridge abutments was determined. The results were compared with previous studies, and the effect of the sediment grain size on the performance of abutment collars was emphasized. It was noticed that when the collar width was increased and it was placed at or below the bed level, the reduction in the maximum local scour depth increases considerably. It was also seen that the change of the sediment size did not affect the optimum location of the collar at the abutment, which yields the maximum scour reduction around the abutment. © 2010 American Society of Civil Engineers.
URI
https://hdl.handle.net/11511/107603
DOI
https://doi.org/10.1061/41147(392)100
Conference Name
5th International Conference on Scour and Erosion
Collections
Graduate School of Natural and Applied Sciences, Conference / Seminar
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. Göğüş and A. E. Dogan, “Effects of collars on scour reduction at bridge abutments,” presented at the 5th International Conference on Scour and Erosion, San Francisco, CA, Amerika Birleşik Devletleri, 2010, Accessed: 00, 2023. [Online]. Available: https://hdl.handle.net/11511/107603.