Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Seismic performance assessment of base isolation systems in five hospitals during the Mw7.8 and Mw7.6 2023 earthquakes in Southeast Turkey
Date
2024-01-01
Author
Kaatsız, Kaan
Alıcı, F. Soner
Sucuoğlu, Haluk
Tanışer, Sadun
Kale, Özkan
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
25
views
0
downloads
Cite This
The February 6, 2023, Kahramanmaraş earthquakes (Mw7.8 and Mw7.6) in Southeast Turkey ruptured a 300 km section of the East Anatolian Fault, resulting in severe ground motions. These two strong earthquakes occurred 9 hours apart and were followed by large-magnitude aftershocks. Strong ground motions from the Kahramanmaraş earthquakes were recorded by more than 280 strong motion stations. Nine base-isolated hospital buildings located at distances less than 50 km from the ruptured fault were subjected to strong ground shaking. This paper examines five of the nine hospitals for which seismic isolation designs were available to the authors. The ground motions acting on these hospital buildings were recorded by strong motion stations situated in close proximity. Consequently, the February 6 earthquakes have presented a unique opportunity to assess the seismic performance of base isolation systems during severe earthquakes. All five hospitals were equipped with double spherical sliding (friction pendulum) seismic isolation devices. Subsequently, the authors conducted site visits to the hospitals following the February 6 earthquakes and collected data on maximum and residual response displacements at their isolation levels, as well as on the seismic response of structural and nonstructural components. The maximum response displacements measured at the isolation levels are compared with the maximum displacements calculated by nonlinear response history analysis under the ground motions recorded at the strong motion stations in close proximity to the hospitals.
Subject Keywords
design displacements
,
February 6 2023
,
maximum isolator displacements
,
rigid mass model
,
seismically isolated hospitals
,
Turkey earthquakes
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85211110791&origin=inward
https://hdl.handle.net/11511/112819
Journal
Earthquake Spectra
DOI
https://doi.org/10.1177/87552930241284613
Collections
Department of Civil Engineering, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
K. Kaatsız, F. S. Alıcı, H. Sucuoğlu, S. Tanışer, and Ö. Kale, “Seismic performance assessment of base isolation systems in five hospitals during the Mw7.8 and Mw7.6 2023 earthquakes in Southeast Turkey,”
Earthquake Spectra
, pp. 0–0, 2024, Accessed: 00, 2024. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85211110791&origin=inward.