Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Standstill Frequency Response Test and Validation of a Large Hydrogenerator
Download
index.pdf
Date
2019-05-01
Author
Belqorchi, Abdelghafour
Karaağaç, Ulaş
Mahseredjian, Jean
Kamwa, Innocent
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
56
views
22
downloads
Cite This
This paper intends to contribute to the revision process of the IEEE Standard 115 by demonstrating the applicability of the standstill frequency response (SSFR) test on large salient pole hydrogenerators. The presented SSFR tests are carried out on a 55.6-MVA salient pole machine with laminated rotor, non-continuous damper windings, and a nonintegral slot number. The IEEE-115 SSFR test procedure is applied with special care to rotor positioning as well as accurate data acquisition in the low-frequency range. The maximum likelihood estimation method is utilized for machine parameter identification from the SSFR tests. Obtained parameters are compared with design values in addition to the ones obtained using traditional "sudden no-load three-phase short-circuit," Dalton-Cameron and "open stator d-axis transient time constant" methods. The accuracy of parameters is also confirmed by comparing the measured three-phase short-circuit current waveforms with the ones obtained by simulating the SSFR-based machine models in an electromagnetic transient -type software. Unlike previous SSFR test cases on large salient pole hydrogenerators, accurate results are obtained.
URI
https://hdl.handle.net/11511/114912
Journal
IEEE TRANSACTIONS ON POWER SYSTEMS
DOI
https://doi.org/10.1109/tpwrs.2018.2889510
Collections
Department of Electrical and Electronics Engineering, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. Belqorchi, U. Karaağaç, J. Mahseredjian, and I. Kamwa, “Standstill Frequency Response Test and Validation of a Large Hydrogenerator,”
IEEE TRANSACTIONS ON POWER SYSTEMS
, no. 3, pp. 2261–2269, 2019, Accessed: 00, 2025. [Online]. Available: https://hdl.handle.net/11511/114912.