Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
A New Control Interaction Phenomenon in Large-Scale Type-4 Wind Park
Download
index.pdf
Date
2023-01-01
Author
Meng, Lei
Karaağaç, Ulaş
Ghafouri, Mohsen
Stepanov, Anton
Mahseredjian, Jean
Chan, Ka Wing
Kocar, Ilhan
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
51
views
68
downloads
Cite This
This paper demonstrates the risk of a new control interaction phenomenon between a large-scale type-4 wind park (WP) and a 500 kV transmission grid in a super-synchronous frequency range. This study aims at (i) using the impedance-based stability assessment (IBSA) method to investigate this new interaction phenomenon, (ii) analyzing the impact of various transmission grid topologies, WP operating conditions, and wind turbine (WT) converter control parameters on the severity of the interaction. For ultimate accuracy, the frequency-dependent impedance characteristics of the WP are extracted using the electromagnetic transient (EMT)-type impedance scanning instead of a simplified analytical model. The performed analyses demonstrate that the WP generation capacity, length of the transmission lines, applied series and shunt compensation levels, presence of parallel lines, and grid side converter (GSC) control parameters of the WT can significantly affect the identified instability risk. The obtained results are validated through detailed EMT simulations. Although the type-4 WP is considered in this paper, the presented results can be generalized to any inverter-based resource (IBR) with a full-size converter (FSC), such as photovoltaic (PV) power stations.
URI
https://hdl.handle.net/11511/114924
Journal
IEEE ACCESS
DOI
https://doi.org/10.1109/access.2023.3334153
Collections
Department of Electrical and Electronics Engineering, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
L. Meng et al., “A New Control Interaction Phenomenon in Large-Scale Type-4 Wind Park,”
IEEE ACCESS
, pp. 132822–132832, 2023, Accessed: 00, 2025. [Online]. Available: https://hdl.handle.net/11511/114924.