Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Re-Examination of DFIG-Based Wind Park Small-Signal Instability
Download
index.pdf
Date
2023-01-01
Author
Xue, Tao
Karaağaç, Ulaş
Cai, Lijun
Kocar, Ilhan
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
1145
views
12
downloads
Cite This
Doubly-fed induction generator-based wind park (DFIG-WP) can interact with both series-capacitor compensated and weak (low short circuit ratio) grids, thus causing instability, and called as series-capacitor sub-synchronous oscillation (SSO) and weak grid SSO, respectively. However, the frequency spectra of phase voltage/current signatures of those two SSOs are significantly different. There is one dominant resonance frequency in series-capacitor SSO, but there are two frequencies (resonance and corresponding mirror frequencies) in weak grid SSO in addition to the fundamental frequency. To address this issue, this paper deeply analyzes the DFIG-WP instability mechanisms through impedance-based stability assessment (IBSA). Both the IBSA and electromagnetic transient (EMT) validation simulations demonstrated that the resonance takes place in the sub-synchronous range in a series-capacitor compensated grid and is mainly affected by the rotor-side converter (RSC) control parameters. However, the weak grid instability is found in the super-synchronous range with its mirror frequency in the sub-synchronous range and is affected by both the RSC and grid-side converter (GSC) control parameters. Therefore, the classification of weak grid SSO needs revision. The utilized DFIG impedance model in IBSA accounts for the DC coupling between RSC and GSC (AC-DC coupling phenomenon). The contribution of this coupling on DFIG impedance and its impact on DFIG-WP instability are demonstrated. In the considered test system, the AC-DC coupling provides a considerable amount of positive resistance in both resonance conditions. Hence, its omission may lead to pessimistic IBSA results. This paper also provides recommendations for instability prevention and/or mitigation through DFIG control parameter modification based on the guidance of the stability contour analysis.
URI
https://hdl.handle.net/11511/114929
Journal
IEEE ACCESS
DOI
https://doi.org/10.1109/access.2023.3340703
Collections
Department of Electrical and Electronics Engineering, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
T. Xue, U. Karaağaç, L. Cai, and I. Kocar, “Re-Examination of DFIG-Based Wind Park Small-Signal Instability,”
IEEE ACCESS
, pp. 141740–141752, 2023, Accessed: 00, 2025. [Online]. Available: https://hdl.handle.net/11511/114929.