Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Enhancing Imaging Performance and Resolution in Magneto-Acoustic Electrical Tomography With Magnetic Field Measurements (MAET-MI) Using Figure-of-Eight and High-Quality Factor Circular Coils
Date
2025-07-01
Author
Tetik, Ahmet Önder
Gençer, Nevzat Güneri
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
606
views
0
downloads
Cite This
Magneto-acousto-electrical tomography with magnetic field measurement technique (MAET-MI) is a hybrid imaging method that brings high spatial resolution of ultrasound imaging in electrical impedance tomography. This study investigates the impact of the quality factor of circular and figure-of-eight coils on the imaging performance of MAET-MI. Induced MAET signals on the circular coil are accurately obtained by modeling a circuit representation of an air-cored circular coil and deriving its transfer function through impedance measurements. The study demonstrates a significant improvement in signal-to-noise ratio (SNR) using high-quality factor coils compared to unity quality factor coils. Additionally, a 16-element linear phased array (LPA) ultrasound transducer, an air core circular coil, and a figure-of-eight coil are numerically modeled to obtain sector scan images of two-dimensional conductivity distributions. Point spread function (PSF) is characterized, and the lateral resolution of sector scan conductivity images is enhanced through two-dimensional deconvolution with PSF. The combined use of circular and figure-of-eight coils provides comprehensive imaging coverage. Notably, this research presents a practical method for estimating both circular and figure-of-eight coils' transfer functions, achieving 12.9 dB SNR improvement with high-quality factor coils. A simplified breast model is rotated 16 steps, and sector scan conductive boundary images are reconstructed for both coils. A two-dimensional image of a breast model is obtained by combining images from two different coils. These findings offer significant advancements in MAET-MI imaging, particularly in low SNR environments.
Subject Keywords
coil
,
delay-and-sum method
,
magneto-acousto-electrical tomography
,
ultrasound imaging
,
wiener filter
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105009892450&origin=inward
https://hdl.handle.net/11511/115306
Journal
International Journal for Numerical Methods in Biomedical Engineering
DOI
https://doi.org/10.1002/cnm.70063
Collections
Department of Electrical and Electronics Engineering, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. Ö. Tetik and N. G. Gençer, “Enhancing Imaging Performance and Resolution in Magneto-Acoustic Electrical Tomography With Magnetic Field Measurements (MAET-MI) Using Figure-of-Eight and High-Quality Factor Circular Coils,”
International Journal for Numerical Methods in Biomedical Engineering
, vol. 41, no. 7, pp. 0–0, 2025, Accessed: 00, 2025. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105009892450&origin=inward.