Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
The Implementation of multi spin echo method for fast T2 weighted imaging in 0.15 tesla magnetic resonance imaging system
Download
068597.pdf
Date
1997
Author
Akpınar, Nezih
Metadata
Show full item record
Item Usage Stats
56
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/1181
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
The design and realization of a low noise 3 to 6 ghz microwave amplifier by use of a cad program
Doğan, Murat; Toker, Canan; Department of Electrical and Electronics Engineering (1992)
The Design and production of interference edge filters with plasma ion assisted deposition technique for a space camera
Barutçu, Burcu; Esendemir, Akif; Department of Physics (2012)
Interference filters are multilayer thin film devices. They use interference effects between the incident and reflected radiation waves at each layer interface to select wavelengths. The production of interference filters depend on the precise deposition of thin material layers on substrates which have suitable optical properties. In this thesis, the main target is to design and produce two optical filters (short-pass filter and long-pass filter) for the CCDs that will be used in the electronics of a space ...
The development of alkaline phosphatase based paper bioreporter for evaluation of milk pasteurization
Karakaş, Ceren; Öktem, Hüseyin Avni; Department of Biotechnology (2009)
Alkaline phosphatase (ALP) is a natural milk enzyme. It has been used as reporter for process controls in food industry. Since ALP denatures at pasteurization temperature (at 63°C or 72°) its detection in milk confirms the unproper pasteurization. There are different detection procedures such as colorimetric, fluorometric methods and immunoassays for ALP in milk. However, they are time consuming processes and require specific instruments and qualified staff. In this study, new, semiquantitative, disposable,...
The development and application of beam tracing algorithm to predict the acoustics of urban design patterns
Şaşmaz, Mehmet; Çalışkan, Mehmet; Department of City and Regional Planning (2003)
THE DEVELOPMENT OF ANCHORING ANALOGY DIAGNOSTIC TEST
YILMAZ, SERKAN; Eryılmaz, Ali (2009-01-01)
The purpose of this study was to develop a measuring tool in order to form teaching materials that can be used in Bridging Analogy Based Instruction (BABI). it would be possible not only to find out new anchoring and bridging analogies, but also to use and investigate the analogies offered in the related literature with this test named as Force Diagnostic Test (FDT). The details of the whole procedure related to the development of the FDT such as selection of the misconceptions, determination of the number ...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
N. Akpınar, “The Implementation of multi spin echo method for fast T2 weighted imaging in 0.15 tesla magnetic resonance imaging system,” Middle East Technical University, 1997.