Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Experimental and Finite Element Investigation of Bolted Connections in GFRP Composite Cross-Arms for Energy Distribution Towers
Download
index.pdf
Date
2026-04-01
Author
Günel Kılıç, Banu
Baran, Eray
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
45
views
12
downloads
Cite This
This study investigates bolted connections in open-section glass fiber-reinforced polymer (GFRP) composite cross-arms for 34.5 kV energy distribution towers. Six GFRP angle sections (L50 × 5 to L120 × 12) were tested under tensile loading using a constant edge distance-to-bolt diameter ratio (e/d = 5), and the connection performance was evaluated based on general maximum and deformation-based criteria (4% and 1 mm hole elongation). Connection capacities ranged from 14.65 to 36.68 kN for single-bolt configurations. Results from multi-bolt connections tests indicated strong influence of bolt layout on connection performance. The highest load capacities of 46.45 kN and 45.93 kN were obtained, respectively, with the two-row bolt configuration and staggered configuration. Comparison of the measured load capacities with ASCE/SEI 74-23 predictions revealed significant discrepancies depending on the assumed failure mode of the connection. A simplified finite element model was developed to predict load–displacement response, capturing initial stiffness and overall trends with reasonable agreement, particularly for connections exhibiting similar failure modes. The findings provide a reliable basis for selecting appropriate bolted connection details in open-section GFRP cross-arm systems.
Subject Keywords
bolted connections
,
composite cross-arm
,
energy distribution tower
,
finite element modeling
,
glass fiber-reinforced polymer
URI
https://hdl.handle.net/11511/119403
Journal
Polymers
DOI
https://doi.org/10.3390/polym18080978
Collections
Graduate School of Informatics, Article
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
B. Günel Kılıç and E. Baran, “Experimental and Finite Element Investigation of Bolted Connections in GFRP Composite Cross-Arms for Energy Distribution Towers,”
Polymers
, vol. 18, no. 8, pp. 0–0, 2026, Accessed: 00, 2026. [Online]. Available: https://hdl.handle.net/11511/119403.