RELIABILITY-ORIENTED DESIGN OF MULTILEVEL INVERTERS FOR MICROGRID APPLICATIONS

2026-8-31
Wereka, Nimrod Kashas
The inclusion of renewable sources into the microgrid architecture highly relies on the DC-AC inverter having the capability to deliver high power quality and no significant downtimes during its entire life cycle. This thesis utilizes simulations to design, analyze and validate a novel 7-switch 5-level hybrid multilevel inverter with power rating of 10 kW and single phase microgrids application, where reliability is taken into account as the most important factor in design process. At first, a 6-switch inverter was designed, however, it could not maintain the +VDC level stability during the simulation process. After adding another two switches and then removing a redundant switch, the final design was obtained, saving 12.5% of the number of active switches. This circuit configuration includes a Neutral Point Clamped DC link with a Hybrid H-Bridge and F-type inverter leg, which operates according to the Phase Disposition PWM (PDPWM) with the switching frequency of 20 kHz, with utilization of the redundant zero voltage levels for capacitor balancing. In the case when it is tested under MATLAB/Simulink simulations, the inverter design is able to keep the Total Harmonic Distortion (THD) of the output voltage under 1.42%, which falls in the range of IEEE 519-2014 limits and it is only 0.36 percentage points away from the 6-switch T-type benchmark from literature. In order to analyze reliability of the circuit, loss-distribution and junction-temperature results are incorporated into the 10,000 iteration Monte Carlo lifetime model, where IGBT wear-out is characterized through Bayerer power-cycling model and DC-link capacitor aging is described by the Arrhenius ripple-current model. On the 24-hour duty cycle, the hybrid achieves the system Mean Time To Failure (MTTF) of 5.1 years, whereas 1.6 years is achieved by the T-type – an increase in the system reliability by 3.2 times or 3.7 times in B10 life, and this is mostly due to the F-type leg, which allows spreading the switching stress and lowering the peak per device losses from 27.3 W to 22.4 W. What is more, the multilevel nature of the design reduces the per-device voltage stress to VDC/2 and reduces the energy loss per switching transition by about 75% as compared to a two-level inverter.
Citation Formats
N. K. Wereka, “RELIABILITY-ORIENTED DESIGN OF MULTILEVEL INVERTERS FOR MICROGRID APPLICATIONS,” M.S. - Master of Science, Middle East Technical University, 2026.