Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Construction of a choline biosensor through enzyme immobilization on a poly(2-hydroxyethyl methacrylate)-grafted Teflon film
Date
2007-06-05
Author
Yucel, Deniz
Ozer, Nazmi
Hasırcı, Vasıf Nejat
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
137
views
0
downloads
Cite This
An amperometric choline biosensor was constructed by immobilizing choline oxidase (ChO) on poly(2-hydroxyethyl methacrylate) (PHEMA)-grafted Teflon (polytetrafluoroethylene, PTFE) film. Grafting was achieved by gamma irradiation. PHEMA-grafted Teflon films were activated with epichlorohydrin or glutaraldehyde to achieve covalent immobilization of enzyme onto the film. To decrease the diffusional barrier caused by the enzyme-immobilized film, the film was stretched directly on the electrode. The PHEMA-grafted Teflon film, therefore, had to have appropriate mechanical properties. Glucose oxidase (GOD) was used in the determination of optimum immobilization conditions, then these were applied to ChO. With GOD, the effect of activation type and film position in electrode on enzyme activity was studied and the highest catalytic activity was obtained when the enzyme was immobilized using glutaraldehyde and the film was stretched over the electrode surface. Further studies revealed that the films activated with glutaraldehyde, immobilized in 2 mg/mL ChO concentration, and stretched directly on the electrode were suitable (specific activity, 0.427 +/- 0.068 U mg(-1)) for use in the choline biosensor. The linear working range of this biosensor was found to be 52-348 mu M, with a 40 +/- 5 mu M minimum detection limit. The response of the sensor, however, decreased linearly upon repeated use. (c) 2007 Wiley Periodicals, Inc. J Appl Polym Sci 104: 3469-3477, 2007.
Subject Keywords
Choline biosensor
,
Choline oxidase
,
Teflon film
,
PHEMA
,
Immobilization
URI
https://hdl.handle.net/11511/31136
Journal
JOURNAL OF APPLIED POLYMER SCIENCE
DOI
https://doi.org/10.1002/app.26174
Collections
Graduate School of Natural and Applied Sciences, Article
Suggestions
OpenMETU
Core
Construction of a choline oxidase biosensor
Yücel, Deniz; Hasırcı, Vasıf Nejat; Özer, Nazmi; Department of Biotechnology (2003)
Choline is indispensable for a number of fundamental processes in the body. Besides being the precursor of the acetylcholine, an important neurotransmitter, choline is found in the cell membrane structure combining with fatty acids, phosphate and glycerol. Its deficiency may result in nervous system disorders, fatty acid build up in the liver, along with increased cholesterol levels, high blood pressure and memory loss. Thus, rapid detection methods are required for the determination of choline in biologica...
Development of Silicalite/Glucose Oxidase-Based Biosensor and Its Application for Glucose Determination in Juices and Nectars
Dudchenko, Oleksandr Ye; Pyeshkova, Viktoriya M.; Soldatkin, Oleksandr O.; Akata Kurç, Burcu; Kasap, Berna O.; Soldatkin, Alexey P.; Dzyadevych, Sergei V. (2016-02-03)
The application of silicalite for improvement of enzyme adsorption on new stainless steel electrodes is reported. Glucose oxidase (GOx) was immobilized by two methods: cross-linking by glutaraldehyde (GOx-GA) and cross-linking by glutaraldehyde along with GOx adsorption on silicalite-modified electrode (SME) (GOx-SME-GA). The GOx-SME-GA biosensors were characterized by a four-to fivefold higher sensitivity than GOx-GA biosensor. It was concluded that silicalite together with GA sufficiently enhances enzyme ...
A novel architecture based on a conducting polymer and calixarene derivative: its synthesis and biosensor construction
GOKOGLAN, Tugba Ceren; SOYLEMEZ, Saniye; KESIK, Melis; UNAY, Hande; Sayin, Serkan; Yildiz, Huseyin Bekir; Çırpan, Ali; Toppare, Levent Kamil (2015-01-01)
In this study, a novel amperometric glucose biosensor based on a selenium comprising conducting polymer and calixarene was developed. Firstly, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]-triazole), poly((SBTz)) was electrodeposited onto a graphite electrode by an electropolymerization technique. Then, a newly synthesized calixarene and gold nanoparticle (AuNP) mixture was used for the improvement of biosensor characteristics. GOx, as a model enzyme was immobilized on the modified electr...
A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite
Soldatkina, O. V.; Soldatkin, O. O.; Kasap, B. Ozansoy; Kucherenko, D. Yu.; Kucherenko, I. S.; Akata Kurç, Burcu; Dzyadevych, S. V. (2017-04-07)
In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via adsorption on silicalite particles. The disc platinum electrode (d = 0.4 mm) was used as the amperometric sensor. The procedure of biosensor preparation was optimized. The main parameters of modifying amperometric transducers with a silicalite layer were determined along with the procedure of GlOx adsorption on this layer. The biosensors based on GlOx adsorbed...
Preparation and characterization of titania-silica-gold thin films over ito substrates for laccase immobilization
Eker, Zeynep; Karakaş, Gürkan; Department of Micro and Nanotechnology (2009)
The aim of this study was to immobilize the redox enzyme laccase over TiO2-SiO2-Au thin film coated ITO glass substrates in order to prepare electrochemically active surfaces for biosensor applications. Colloidal TiO2-SiO2-Au solution was synthesized by sol-gel route and thin film was deposited onto the substrates by dipcoating method. The cysteamine was utilized as a linker for immobilization of enzyme covalently through gold active sites. Preliminary studies were conducted by using invertase as model enzy...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
D. Yucel, N. Ozer, and V. N. Hasırcı, “Construction of a choline biosensor through enzyme immobilization on a poly(2-hydroxyethyl methacrylate)-grafted Teflon film,”
JOURNAL OF APPLIED POLYMER SCIENCE
, pp. 3469–3477, 2007, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/31136.