Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
PROGRAMMABLE BALANCING ADC WITH RESIDUE CODING
Date
1991-06-01
Author
Alıyev, Tahmasıb
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
87
views
0
downloads
Cite This
Subject Keywords
Instrumentation
,
Applied Mathematics
URI
https://hdl.handle.net/11511/35603
Journal
MEASUREMENT TECHNIQUES USSR
DOI
https://doi.org/10.1007/bf00978755
Collections
Department of Physics, Article
Suggestions
OpenMETU
Core
An instrument for the high temperature measurement of the Seebeck coefficient and electrical resistivity
GÜNEŞ, Murat; Parlak, Mehmet; Ozenbas, Macit (IOP Publishing, 2014-05-01)
A system for the simultaneous measurement of thermoelectric power and resistivity of one and/ or two samples over a temperature range of 300-1000 K in a vacuum chamber is designed and implemented. A sample probe is developed to provide its easy mounting and usage. In addition, two samples can be measured at the same time. Measurement accuracy has been enhanced by beadless thermocouples and micro-heaters that are specifically designed in order to minimize the 'cold-finger effect' and to eliminate some possib...
A NEW CRYOSTAT AND TEMPERATURE CONTROLLER FOR TSC MEASUREMENTS
OZDEMIR, S; DEMIRBAS, A; OZAVCI, E (IOP Publishing, 1993-03-01)
A linear temperature controller and a cryostat have been developed to measure thermally stimulated current (TSC) in CdS, a-Si:H and CdTe in order to determine the trapping characteristic. In this paper, the temperature controller and the cryostat are described in detail. In addition, TSC spectra, at five different heating rates, for a CdS thin-film sample recorded with the developed system are given, The system controls the linear heating of a sample at temperatures between about 100 K and 373 K. The temper...
Deconvolution Kalman filtering for force measurements of revolving wings
Vester, R.; Perçin, Mustafa; van Oudheusden, B. (IOP Publishing, 2016-09-01)
The applicability of a deconvolution Kalman filtering approach is assessed for the force measurements on a flat plate undergoing a revolving motion, as an alternative procedure to correct for test setup vibrations. The system identification process required for the correct implementation of the deconvolution Kalman filter is explained in detail. It is found that in the presence of a relatively complex forcing history, the DK filter is better suited to filter out structural test rig vibrations than conventio...
RECONSTRUCTION OF THE DISTRIBUTION FUNCTION OF RANDOM ERRORS IN THE CLASS OF NAZAROV,IA DISTRIBUTIONS
Alıyev, Tahmasıb (Springer Science and Business Media LLC, 1992-03-01)
RECURRENT LOGARITHM ADC BASED ON BRIGGS METHOD
Alıyev, Tahmasıb (Springer Science and Business Media LLC, 1991-07-01)
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
T. Alıyev, “PROGRAMMABLE BALANCING ADC WITH RESIDUE CODING,”
MEASUREMENT TECHNIQUES USSR
, pp. 525–530, 1991, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/35603.