Comparison of dry, wet, and microwave ashing methods for the determination of Al, Zn, and Fe in yogurt samples by atomic absorption spectrometry

2005-01-01
Yaman, Mehmet
Durak, Muhammed
Bakirdere, Sezgin
Digestion methods such as dry and wet ashing and microwave oven were examined at various conditions to determine a rapid, reliable, and simple digestion procedure for yogurt. Digestion by microwave oven was found to be an excellent method in comparison with dry and wet ashing methods when only A1 and Zn in yogurt samples were determined. Iron in this matrix is not completely digested by the microwave oven method at the examined conditions. From the obtained results, yogurt can also be a good source of essential nutrients such as minerals in human diet, especially zinc. Aluminum concentrations in yogurt samples fermented in A1 containers were found to be significantly higher than in plastic containers. Al concentrations of yogurt taken from the bottom of the container were found to be higher than from the center and top of Al containers. The determinations of metals were carried out via an atomic absorption spectrophotometer using calibration curve and standard additions methods. Aluminum concentrations in yogurt samples produced in big production centers were found to be significantly higher than the other yogurt samples produced in-house when plastic containers were used.
SPECTROSCOPY LETTERS

Suggestions

Quality improvement in determination of chemical oxygen demand in samples considered difficult to analyze, through participation in proficiency-testing schemes
Raposo, F.; Fernandez-Cegri, V.; De la Rubia, M. A.; Borja, R.; Beltran, J.; Cavinato, C.; Clinckspoor, M.; Demirer, Göksel Niyazi; Diamadopoulos, E.; Frigon, J. C.; Koubova, J.; Launay, M.; Mendez, R.; Menin, G.; Noguerol, J.; Uellehdahl, H.; West, S. (Elsevier BV, 2010-10-01)
Chemical oxygen demand (COD) is a critical analytical parameter in waste and wastewater treatment, more specifically in anaerobic digestion, although little is known about the quality of measuring COD of anaerobic digestion samples. Proficiency testing (PT) is a powerful tool that can be used to test the performance achievable in the participants' laboratories, so we carried out a second PT of COD determination in samples considered "difficult" to analyze (i.e. solid samples and liquid samples with high con...
Raman Spectroscopy Investigation of Nano Hydroxyapatite Doped with Yttrium and Fluoride Ions
Yilmaz, Bengi; Evis, Zafer (Informa UK Limited, 2014-01-02)
In this study, nano hydroxyapatite doped with yttrium (2.5, 5, and 7.5mol%) and fluoride (2.5mol%) ions were synthesized by precipitation method and sintered at 900 degrees C, 1100 degrees C, and 1300 degrees C. Raman spectroscopy was applied to track the structural modifications in pure and doped hydroxyapatites. The results showed that the main characteristic band of pure hydroxyapatite at 963cm(-1) was not affected significantly by ion doping but exhibited higher intensity with increasing sintering tempe...
Calculation of the Raman frequencies of the translational mode in ammonia solid II
Yurtseven, Hasan Hamit (Elsevier BV, 2003-03-01)
We report here our calculated Raman frequencies of the translational mode as a function of temperature for the. fixed pressures of 3.65, 5.02 and 6.57 kbars in the ammonia solid II. They were calculated by means of our Gruneisen relation using the volume data from the literature for all the pressures indicated within the temperature regions close to the melting point in this system. Our calculated frequencies are in very-good agreement with those observed experimentally for this translational mode of the am...
Determination of absolute transport efficiencies of Be, Cd, In, Pb and Bi for electrothermal vaporization sample introduction into an inductively coupled plasma using an in-line electrostatic precipitator
Ertaş, Gülay (Elsevier BV, 2003-09-26)
A novel laboratory-constructed electrostatic precipitator for the determination of analyte transport efficiencies from a tube furnace electrothermal vaporization (ETV) sample introduction system is described. This simple experimental set up captures the analyte electrostatically using a negative corona discharge. The absolute transport efficiencies using experimental conditions typical of those applied to real analysis by ETV-ICP-MS were determined for Be, Cd, In, Pb and Bi to be 26 +/- 3, 39 +/- 8, 35 +/- ...
Development of sensitive analytical methods for the determination of thallium at trace levels by slotted quartz tube flame atomic absorption spectrometry
Ari, Betul; BAKIRDERE, Sezgin; Ataman, Osman Yavuz (Elsevier BV, 2020-09-01)
A simple, sensitive and economical technique is needed for the determination of thallium and this study demonstrates the different analytical strategies were developed using atomic absorption spectrometry (AAS). In order to improve the sensitivity of flame atomic absorption spectrometry (FAAS), a basic slotted quartz tube (SQT) was used for the thallium determination. In the first strategy, mixing propanol (100 mu L) and Tl standard solution (500 mu L) under the optimum conditions, namely solvent assisted S...
Citation Formats
M. Yaman, M. Durak, and S. Bakirdere, “Comparison of dry, wet, and microwave ashing methods for the determination of Al, Zn, and Fe in yogurt samples by atomic absorption spectrometry,” SPECTROSCOPY LETTERS, pp. 405–417, 2005, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/57657.