Quasi-optical diffraction tomography system

2000-08-03
Adiguzel, T
This work is devoted to the diffraction tomography in millimeter wavelength band. It is used for reconstruction of the images of volumetric objects. With the help of this method one can study internal structure of distant nondestructive objects
2nd International Conference on Subsurface Sensing Technologies and Applications

Suggestions

Induced Current Magnetic Resonance Electrical Conductivity Imaging With Oscillating Gradients
Eroglu, Hasan H.; Sadighi, Mehdi; Eyüboğlu, Behçet Murat (2018-07-01)
In this paper, induced current magnetic resonance electrical impedance tomography (ICMREIT) by means of current induction due to time-varying gradient fields of magnetic resonance imaging (MRI) systems is proposed. Eddy current and secondary magnetic flux density distributions are calculated for a numerical model composed of a z-gradient coil and a cylindrical conductor. An MRI pulse sequence is developed for the experimental evaluation of ICMREIT on a 3T MRI scanner. A relationship between the secondary ma...
Ray anlaysis of electromagnetic scattering from semi-infinite array of dipoles in free space
Polat, Özgür Murat; Aydın Çivi, Hatice Özlem; Department of Electrical and Electronics Engineering (2007)
Electromagnetic wave scattering from a semi-infinite array of dipoles in free space is described by using asymptotic high frequency methods. An electric field integral expression is obtained and solved with asymptotic high frequency methods. An asymptotic field expression is obtained for a finite × infinite array of dipoles in free space. The analytical closed form expression for the array guided surface wave launching coefficient is obtained via a combination of an asymptotic high frequency analysis of a r...
Multi-frequency contactless electrical impedance imaging using realistic head models : single coil simulations
Gürsoy, Doğa; Ertan, Hulusi Bülent; Department of Electrical and Electronics Engineering (2007)
Contactless electrical impedance imaging technique is based upon the measurement of secondary electromagnetic fields caused by induced currents inside the body. In this study, a circular single-coil is used as a transmitter and a receiver. The purpose of this study is twofold: (1) to solve the induced current density distribution inside the realistic head model resulting from a sinusoidal excitation, (2) to calculate the impedance change of the same coil from the induced current distribution inside the head...
Equipotential projection based MREIT reconstruction without potential measurements
Eyüboğlu, Behçet Murat (2007-09-02)
Magnetic resonance electrical impedance tomography (MREIT) is used to produce high resolution images of true conductivitv distribution. Images are reconstructed by utilising measurements of magnetic flux density distribution and surface potentials. Surface potential measurements are needed to reconstruct true conductivity values. In this study, a novel MREIT reconstruction algorithm is developed to generate conductivity images without utilizing the surface potential measurements. The proposed algorithm and ...
High performance short wavelength infrared focal plane arrays
Çırçır, Kübra; Beşikci, Cengiz; Department of Electrical and Electronics Engineering (2017)
Short Wavelength Infrared (SWIR) band is desirable for many applications such as night vision, spectroscopy and hyperspectral imaging. Indium Gallium Arsenide (In0.53Ga0.47As) is a suitable material for SWIR photodetectors. This thesis focuses on the investigation of the pixel characteristics of a 15 µm pitch large format (640x512) focal plane array (FPA) with In0.53Ga0.47As absorber and Al0.52In0.48As p-type cap layers as an alternative to the conventional In0.53Ga0.47As detectors utilizing InP as the p-ca...
Citation Formats
T. Adiguzel, “Quasi-optical diffraction tomography system,” San Diego, CA, 2000, vol. 4129, p. 578, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/63403.