Energy conscious dwelling design for Ankara

Download
2000-01-01
Demirbilek, FN
Yalciner, UG
Inanici, MN
Ecevit, A
Demirbilek, OS
The study aims to develop energy conscious dwellings in climatic conditions of Ankara. Since the computer program SUNCODE-PC is used for thermal performance analysis, an hourly climatic data set for an average year has been prepared. Two design proposals are developed and compared: one of them is designed with conventional features and the other is designed energy consciously. Improvement studies are conducted on the energy conscious design.
BUILDING AND ENVIRONMENT

Suggestions

Energy indicators for sustainable development: comparison of Turkey and selected european union countries
Toğçuoğlu, Mehlika Merve; Aşık, Serap; Akbostancı Özkazanç, Elif; Department of Economics (2011)
The aim of this study is to compare the sustainable development perspective of Turkey with selected European Union countries in terms of Energy Indicators for Sustainable Energy between 1980-2008. The study is conducted in a comparative and descriptive way by using energy indicators. The common energy policy priorities of Turkey and European Union are determined in the light of recent literature. An energy indicator set is constructed according to energy priorities, namely, energy efficiency and energy inte...
Konut Alanlarında Enerji Etkinliği: Toplu Konut İdaresi Başkanlığı (Toki) Toplu Konut Projeleri Üzerine Eleştirel Bir Değerlendirme
Karaca, Mehmet; Varol, Çiğdem (Middle East Technical University, Faculty of Architecture, 2012-12-1)
The rapid increase in energy demand and consumption has intensified the necessity of developing new methods to ensure energy efficiency. When heating, cooling, lighting and other equipments in buildings are accounting for 24% of total energy consumption, it is inevitable to take more initiatives to reduce energy consumption in the construction sector. New residential areas cannot anymore be the places, where natural resources are consumed recklessly. They should be designed as livable areas, where preservin...
Architecture, ideology, representation : party headquarters as a new mode in representing power since the 1980’s
Yılmaz, Fadime; Sargın, Güven Arif; Department of Architecture (2009)
The main objective of this study is to question the potential of architecture as a representational medium of ideology. In order to exemplify this overlapping relationship between ideology and architecture, this study focuses on the headquarters erected by major parties of Turkey since the 1980’s. Having a significant position within society and particularly being a part of political system, parties obviously define ideological formations in order to preserve their existence and also strengthen their positi...
Solar energy R&D, technology and economics in Turkey
Taşdemiroğlu, E (Elsevier BV, 1990-1)
The solar energy potential of Turkey is assessed. Solar energy R&D programs and technology and the present market for flat-plate solar collectors are briefly reviewed. The potential share of solar energy in the total energy budget is estimated.
Assessing thermal comfort conditions: a case Study on the METU Faculty of Architecture building; the case of ODTÜKENT
Çakır, Çağrı; Elias Özkan, Soofia Tahira; Department of Building Science in Architecture (2006)
The aim of this study was to evaluate the effects of environmental design parameters on thermal comfort conditions in the METU Faculty of Architecture Building located in Ankara. The building had some problems in terms of indoor climatic conditions, both in winter and in summer. It was evident that some design parameters caused this undesirable situation. The study therefore focused on understanding and evaluating the effects of design-dependent elements such as thermal mass, the size and orientation of win...
Citation Formats
F. Demirbilek, U. Yalciner, M. Inanici, A. Ecevit, and O. Demirbilek, “Energy conscious dwelling design for Ankara,” BUILDING AND ENVIRONMENT, pp. 33–40, 2000, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/68086.