A Complete Analysis for Pump Controlled Single Rod Actuator

2016-03-08

Suggestions

A Complete Analysis for Pump Controlled Single Rod Actuators
Çalışkan, Hakan; Balkan, Raif Tuna (null; 2016-03-07)
In the current study a variable speed pump controlled hydrostatic circuit where an underlapped shuttle valve is utilized to compensate the unequal flow rate of a single rod actuator is analyzed. Parameters of the shuttle valve are included in the system analysis, rather than treating it as an ideal switching element as handled in literature. A linearized model of the system is obtained. An inverse kinematic model, which calculates the required pump drive speed for a desired actuator speed and given pilot pr...
A Case study for calculating and reporting the uncertainty budget of 1 and 2 dimensional combined hydraulic model
Gül, Uğraş Sidar; Altan Sakarya, Ayşe Burcu; Department of Civil Engineering (2019)
This study aims to suggest a framework to quantify and report the uncertainty budget of a 1 & 2 dimensional hydraulic model of five possible error sources by using ISO GUM method. The river engineers take into account several considerations when they design the riverbeds; one of the main considerations is the flood protection aspect of the riverbed, to asses that a hydraulic model is usually prepared. However, results generated from the hydraulic models are not exempt from errors. The ISO GUM method provide...
A Complete Simplified Framework in Determination of Seismic Racking Response of Shallow Buried Structures
Özcebe, Ali Güney; Çetin, Kemal Önder (2012-09-28)
A Case study on planning of combined gravity and pumping irrigartion system Girmir
Çağlayan Varlık, Aylin; Uluatam, Semra Siber; Department of Civil Engineering (1996)
A Detailed Analysis for the Absorption Coefficient of Multilevel Uncooled Infrared Detectors
Küçük, Serhat; Akın, Tayfun (2011-04-29)
This paper introduces a detailed analysis on the calculation of the absorption coefficient of multilevel uncooled infrared detectors. The analysis is carried out considering a two-level 25 mu m pixel pitch infrared detector with a sandwich type resistor which is divided into sub-regions consisting of different stacks of layers. The absorption coefficients of these different sub-regions are calculated individually by using the cascaded transmission line model, including the main body, arms, and the regions w...
Citation Formats
H. Çalışkan and R. T. Balkan, “A Complete Analysis for Pump Controlled Single Rod Actuator,” 2016, vol. 2, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/72271.