Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Performance-based seismic design of isolated bridges using gapped damping device connections
Date
2018-09-28
Author
Dicleli, Murat
Metadata
Show full item record
Item Usage Stats
82
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/75816
Collections
Unverified, Conference / Seminar
Suggestions
OpenMETU
Core
Performance-based seismic design of a major viaduct using torsional dampers
Dicleli, Murat (2015-12-20)
Performance-Based Seismic Design of Bitlis River Viaduct Based on Damage Control Using Seismic Isolation and Energy Dissipation Devices
Dicleli, Murat (2017-05-28)
This paper presents a sample application of seismic isolation techniques in performance-based design of a major viaduct. The Bitlis River viaduct is located in a seismically active region. The targeted performance goal required no damage at 475-year return period earthquake and repairable damage at 2475-year return period earthquake. The bridge is designed with a seismic isolation system composed of spherical bearings and MRSD (Multidirectional Re-centering steel Damper) hysteretic dampers. The MRSD is a re...
Performance of seismic-isolated bridges with and without elastic-gap devices in near-fault zones
Dicleli, Murat (2008-05-01)
In this paper, the efficiency of providing elastic-gap devices (EGDs) to improve the performance of seismic- isolated bridges (SIBs) in near-fault (NF) zones is investigated. The device is primarily made of an assembly of circular rubber bearings and steel plates to provide additional elastic stiffness to the SIB upon closure of a gap. The EDG is intended to function at two performance levels under service and maximum considered design level (MCDL) NF earthquakes to reduce isolator displacements while keepi...
Performance assesment of indium antimonide photodetectors on silicon substrates
Tümkaya, Ümid; Günal, İbrahim; Beşikçi, Cengiz; Department of Physics (2003)
In this study, detailed characteristics and performance assessment of 3-5 æm p-i-n InSb photodetectors on Si substrates are reported. The detector epilayers were grown on GaAs coated Si substrates by molecular beam apitaxy (MBE). Both homojunction and single heterojunction (AlInSb/InSb) detector structures were investigated. Arrays of 33x33 æm2 detectors were fabricated and flip-chip bonded to a test substrate for detailed electrical and optical characterization. A peak detectivity as high as 1x1010 cmHz1/2...
Performance anallysis of an intermediate temperature solid oxide fuel cell
Timurkutluk, Bora; Tarı, İlker; Department of Mechanical Engineering (2007)
An intermediate temperature solid oxide fuel cell (SOFC) is developed and its performance is investigated experimentally and theoretically. In the experimental program, a gadolinium doped ceria based membrane electrode group is developed with the tape casting and screen printing methodology and characterized. An experimental setup is devised for the performance measurement of SOFCs and the performance of produced cells is investigated over a range of parameters including the electrolyte thickness, the sinte...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. Dicleli, “Performance-based seismic design of isolated bridges using gapped damping device connections,” 2018, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/75816.