Influence of FRP Reinforcement Ratio on the Ductility Values of Concrete Beams with Hybrid FRP-Steel Reinforcement

2018-09-14
Kartal, Saruhan
Kalkan, İlker
Mertol, Halit Cenan
Baran, Eray
13th İnternational congress onadvances in civil engineering

Suggestions

Influence of the proportion of FRP to steel reinforcement on the strength and ductility of hybrid reinforced concrete beams
KARTAL, SARUHAN; KALKAN, İLKER; MERTOL, HALİT CENAN; Baran, Eray (2022-11-01)
The present study pertains to the influence of variation of FRP (Fiber Reinforced Polymer) proportion in tension reinforcement on the flexural behavior of RC beams with FRP and steel reinforcing bars. A total of 25 beams, including FRP-, steel- and hybrid FRP-steel reinforced ones, were tested to failure under four-point bending. Two types of FRP bars, GFRP (Glass Fiber Reinforced Polymer) and BFRP (Basalt Fiber Reinforced Polymer), were used and both over- and under-reinforced beams were tested. The beams ...
Influence of the shear wall area to floor area ratio on the seismic performance of existing reinforced concrete buildings
Günel, Ahmet Orhun; Burak Bakır, Burcu; Department of Civil Engineering (2013)
An analytical study is performed to evaluate the influence of shear wall area to floor area ratio on the behavior of existing mid-rise reinforced concrete buildings under earthquake loading. The seismic performance of five existing school buildings with shear wall ratios between 0.00% and 2.50% in both longitudinal and transverse directions and their strengthened counterparts are evaluated. Based on the structural properties of the existing buildings, additional buildings with varying shear wall ratios are ...
Influence of the nitrogen flow rate on the order and structure of PECVD boron nitride thin films
Anutgan, M.; Anutgan, T. Aliyeva; Ozkol, E.; Atilgan, I.; Katircioglu, B. (2009-09-01)
Three sets of boron nitride (BN) thin films are deposited with different N(2)/B(2)H(6) flow ratios (r = 4, 10 and 25) by plasma enhanced chemical vapor deposition (PECVD). The variations of physical properties in different deposition sets are analyzed by optical (XPS, FTIR, UV-visible spectroscopies), mechanical and electrical measurements. The films are considered to be deposited in a turbostratic phase (t-BN). Evolution of bonding configurations with increasing r is discussed. Relatively higher nitrogen f...
Influence of Phase Magnetic Couplings on Phase Current Characteristics of Multiphase BLDC Machines with Overlapping Phase Windings
Bostancı, Emine; Plikat, Robert (2015-09-01)
Multiphase brushless dc (BLDC) machines are implemented in electric and hybrid electric vehicle applications due to their high torque/power density, good fault tolerance capability, and low torque ripple. Moreover, the per-phase converter rating can be reduced by increasing the phase number. However, the number of magnetic couplings between phases increases with the phase number, and these magnetic couplings can have an important influence on the machine performance. Therefore, they need to be considered in...
Influence of Shear Wall Index on the Seismic Performance of Reinforced Concrete Buildings
Burak Bakır, Burcu; Yakut, Ahmet (null; 2009-06-22)
Citation Formats
S. Kartal, İ. Kalkan, H. C. Mertol, and E. Baran, “Influence of FRP Reinforcement Ratio on the Ductility Values of Concrete Beams with Hybrid FRP-Steel Reinforcement,” presented at the 13th İnternational congress onadvances in civil engineering, 2018, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/83371.