Experimental investigation of two shared stroge assigment policies in AS/RS under continuous reviw (Q, r) inventory policy

Download
1996
Kültürel, Şadan

Suggestions

Experimental investigation of the different shared storage assignment policies in the end-of-aisle AS/R systems
Bozkurt, Zafer; Sepil, Canan; Department of Industrial Engineering (1995)
Experimental investigation of spatially-periodic scalar patterns in an inline mixer
Başkan Perçin, Özge; Speetjens, Michel; Clercx, Herman (2015-11-22)
Experimental Evaluation of Panel-Method-Based Path Planning for eVTOL in A Scaled Urban Environment
Ünal, Zeynep; Bronz, Murat; Yavrucuk, İlkay (2022-01-01)
In this study, previously proposed panel method based path planning for electric vertical take off and landing vehicles in urban environments is tested in a high fidelity simulation environment and with real-life drones in an indoor flight arena. Panel method is a numerical tool, borrowed form fluid dynamics domain, that can generate collision free paths for multiple vehicles in environments with arbitrarily shaped obstacles while guaranteeing obstacle avoidance and convergence to global minima with little ...
Experimental evaluation of the in-plane behaviour of masonry wall infilled RC frames
Suzuki, Tomomi; Choi, Ho; Sanada, Yasushi; Nakano, Yoshiaki; Matsukawa, Kazuto; Paul, Devjyoti; Gulkan, Polat; Binici, Barış (2017-10-01)
This study focuses on the in-plane behaviour of unreinforced masonry (URM) infill walls installed in reinforced concrete (RC) frames. Five 1/4-scale model frames were designed based on a prototype RC building with URM infill walls in Turkey. The experimental parameters were the layout of the URM infill (its presence or absence), number of spans (single or double), number of stories (single or double), and stacking pattern of the URM infill (horizontal or vertical). Static cyclic loading tests were conducted...
Experimental study of single and multiple outlets behavior under constant head
Çobanoğlu, İsmail; Tiğrek, Şahnaz; Department of Civil Engineering (2008)
The performance of outlets under constant head is investigated in this study. Behavior of single outlet is analyzed; subsequently effect of multiple outlets on a single outlet is examined. Parameters taken into account are constant head of water, orifice shape, orifice length, number of open outlets and discharge. The outlet type, which is examined, can be classified as a short tube orifice. Two different orifice diameters and tube lengths are used. Outlets had the diameter, 6.00 and 10.35mm. The ratio of o...
Citation Formats
Ş. Kültürel, “Experimental investigation of two shared stroge assigment policies in AS/RS under continuous reviw (Q, r) inventory policy,” Middle East Technical University, 1996.