Single-image Bayesian Restoration and Multi-image Super-resolution Restoration for B-mode Ultrasound Using an Accurate System Model Involving Correlated Nature of the Speckle Noise.

2019-11-01
Cüneyitoğlu, Özkul
Mumcuoğlu, Ünal Erkan
Sancak, İT
B-mode ultrasound is an essential part of radiological examinations due to its low cost, safety, and portability, but has the drawbacks of the speckle noise and output of most systems is two-dimensional (2D) cross sections. Image restoration techniques, using mathematical models for image degradation and noise, can be used to boost resolution (deconvolution) as well as to reduce the speckle. In this study, new single-image Bayesian restoration (BR) and multi-image super-resolution restoration (BSRR) methods are proposed for in-plane B-mode ultrasound images. The spatially correlated nature of the speckle was modeled, allowing for examination of two different models for BR and BSRR for uncorrelated Gaussian (BR-UG, BSRR-UG) and correlated Gaussian (BR-CG, BSRR-CG). The performances of these models were compared with common image restoration methods (Wiener filter, bilateral filtering, and anisotropic diffusion). Well-recognized metrics (peak signal-to-noise ratio, contrast-to-noise ratio, and normalized information density) were used for algorithm free-parameter estimation and objective evaluations. The methods were tested using superficial tissue (2D scan data collected from volunteers, tissue-mimicking resolutions, and breast phantoms). Improvement in image quality was assessed by experts using visual grading analysis. In general, BSRR-CG performed better than all other methods. A potential downside of BSRR-CG is increased computation time, which can be addressed by the use of high-performance graphics processing units (GPUs).
Ultrasonic imaging

Suggestions

Electrical impedance imaging developed to image cardiopulmonary function
Brown, Brian Hilton; Barber, David; Eyüboğlu, Behçet Murat ( IEEE; 1987-11-01)
Electrical impedance imaging allows functional images to be produced at low cost, high speed, and no hazard to the patient. The system developed uses 16 electrodes placed around the thorax. The technique of Applied Potential Tomography (APT) described by the authors produces tomographic images of resistivity changes from data collected at 24 frames/s. The spatial resolution and sensitivity are sufficient to image lung ventilation and the movement of blood during the cardiac cycle. As blood has a relatively ...
Microcontroller controlled, multifrequency electrical impedance tomograph
Arpınar, VE; Eyüboğlu, Behçet Murat (2001-10-28)
In this study, development of a microcontroller controlled multifrequency electrical impedance tomography system is aimed. In this system, current injection and voltage measurements are both performed by the surface electrodes, which are microcontroller controlled. Data acquisition system process the measured signal using continuous time quadrature demodulator. After that, it converts analog information to digital and transfers it to the PC.
Coil sensitivity map calculation using biot-savart law at 3 tesla and parallel imaging in MRI
Esin, Yunus Emre; Alpaslan, Ferda Nur; Department of Computer Engineering (2017)
Coil spatial sensitivity map is considered as one of the most valuable data used in parallel magnetic resonance imaging (MRI) reconstruction. In this study, a novel sensitivity map extraction method is introduced for phased-array coils. Proposed technique uses Biot-Savart law with coil shape information and low-resolution phase image data to form sensitivity maps. The performance of this method has been tested in the parallel image reconstruction task using sensitivity encoding technique. In MRI, coil sensi...
Thin Film PZT Acoustic Sensor for Fully Implantable Cochlear Implants
İlik, Bedirhan; Koyuncuoğlu, Aziz; Uluşan, Hasan; Chamanıan, Salar; Işık Akçakaya, Dilek; Şardan Sukas, Özlem; Külah, Haluk (2017-09-06)
This paper presents design and fabrication of a MEMS-based thin film piezoelectric transducer to be placed on an eardrum for fully-implantable cochlear implant (FICI) applications. Resonating at a specific frequency within the hearing band, the transducer senses eardrum vibration and generates the required voltage output for the stimulating circuitry. Moreover, high sensitivity of the sensor, 391.9 mV/Pa @900 Hz, decreases the required power for neural stimulation. The transducer provides highest voltage ou...
Fast 3D reconstruction from medical image series based on thresholding method Eşikleme metodunu kullanarak medikal görüntü serisinden hizli 3 boyutlu model oluşturma
Öz, Sinan; Serinağaoğlu Doğrusöz, Yeşim (2010-07-15)
Many practical applications in the field of medical image processing need valid, reliable and fast image segmentation. In this study, we propose a semi-automatic segmentation approach. In this approach, an extended version of the Otsu's method for three level thresholding and a recursive connected component algorithm are combined. The segmentation process is accomplished using Extended Otsu's method and labeling in each consecutive slice. Extended Otsu's method is a thresholding method selecting two thresho...
Citation Formats
Ö. Cüneyitoğlu, Ü. E. Mumcuoğlu, and İ. Sancak, “Single-image Bayesian Restoration and Multi-image Super-resolution Restoration for B-mode Ultrasound Using an Accurate System Model Involving Correlated Nature of the Speckle Noise.,” Ultrasonic imaging, pp. 368–386, 2019, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/30056.