Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Determination of bismuth using on-line preconcentration by trapping on resistively heated W coil and hydride generation atomic absorption spectrometry
Date
2002-01-01
Author
Cankur, O
Ertas, N
Ataman, Osman Yavuz
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
131
views
0
downloads
Cite This
A novel analytical system was developed to trap and preconcentrate bismuth from the vapour phase stream. Bismuthine formed by sodium tetrahydroborate reduction was trapped on a tungsten coil previously heated to 270 degreesC. The analyte species were re-volatilised by increasing the coil temperature to 1200 degreesC and then transported to an externally heated silica T-tube by using a mixture of argon and hydrogen as the carrier gas. The base width of the transient signal was less than 0.5 s. The reproducibility of the analytical signal was influenced by the rate of heating of the tungsten coil at the releasing stage. The precision of the analytical system was found to be 5.8% RSD (n = 13) for 0.010 ng ml(-1) Bi when peak height was used. Due to sharp signals, peak area readings gave higher RSD values but they could be used for quantitation. The relationship between the analytical signal and the sample volume was found to be linear between 0.5 ml and 60 ml when using 0.100 ng ml(-1) Bi. When the sample volume was increased to 25 ml, the blank values became significant. The calibration plot for an 18 ml sampling volume was linear between 0.030 and 0.500 ng ml(-1) Bi. A limit of detection of 0.0027 ng ml(-1) (3s) was obtained with 18 ml of sample volume. The concentration limit of detection achieved was comparable with or better than those obtained by techniques such as ICP-MS and HG-ETAAS. When the distance between the trap and atomiser was increased to 200 cm, a 72% and 24% decrease was observed in the peak height and peak area, respectively. In order to validate the accuracy of the method, two geological standard reference materials and one certified water standard reference material were analysed and the results were found to be in good agreement with the certified values at the 95% confidence level.
Subject Keywords
Nebulization
,
System
,
Cadmium
,
Samples
,
Urine
,
Forming elements
,
Forming elements
,
Graphite-furnace
,
Tungsten coil
,
In-situ preconcentration
,
Plasma-mass spectrometry
URI
https://hdl.handle.net/11511/30603
Journal
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
DOI
https://doi.org/10.1039/b201365g
Collections
Graduate School of Natural and Applied Sciences, Article
Suggestions
OpenMETU
Core
Determination of antimony by using a quartz atom trap and electrochemical hydride generation atomic absorption spectrometry
Menemenlioglu, Ipek; Korkmaz, Deniz; Ataman, Osman Yavuz (2007-01-01)
The analytical performance of a miniature quartz trap coupled with electrochemical hydride generator for antimony determination is described. A portion of the inlet arm of the conventional quartz tube atomizer was used as an integrated trap medium for on-line preconcentration of electrochemically generated hydrides. This configuration minimizes transfer lines and connections. A thin-layer of electrochemical flow through cell was constructed. Lead and platinum foils were employed as cathode and anode materia...
Determination of antimony by using tungsten trap atomic absorption spectrometry
TİTRETİR DURAN, SERAP; Kenduezler, Erdal; Arslan, Yasin; KULA, İBRAHİM; Bakirdere, Sezgin; Ataman, Osman Yavuz (2008-08-01)
An electrically heated tungsten coil was used as a trap in the determination of antimony. The technique consists of three steps. Initially, SbH(3) is formed by hydride generation procedure; then the analyte species in vapor form are transported to W-coil trap heated at 370 degrees C. Following the preconcentration step, the trap is heated to 895 degrees C; analyte species are revolatilized and transported to the flame-heated quartz atom cell where atornization and the formation of signal take place. The exp...
Determination of cadmium using slotted quartz tube atom trap atomic absorption spectrometry and metal coatings
Özcan Gurbetçioğlu, G. Pelin; Ataman, Osman Yavuz; Department of Chemistry (2010)
Flame atomic absorption spectroscopy (FAAS) is a common technique for detecting metals and metalloids in environmental, biological and metallurgical samples. Although it is a rather old technique, it is still very reliable, simple to use and inexpensive. The technique can be used to determine the concentration of over 70 different metals in a solution. However, it has detection limits at mg/L levels. Some atom trapping methods have been developed to reach the detection limits of ng/mL levels. Slotted quartz...
Determination of silver by chemical vapour generation and atomic absoption spectrometry
Öztürk, Çağla Pınar; Ataman, Osman Yavuz; Department of Chemistry (2004)
A method for determination of silver has been developed based on chemical vapour generation atomic absorption spectrometry (CVGAAS). Volatile species of silver in acidified medium were generated by the reduction of sodium tetrahydroborate; these species were sent to a flame-heated quartz tube atomizer (QTA) following isolation by using a gas-liquid separator. Flow injection (FI) was used for sample introduction. Optimization of parameters such as; concentrations of acid and NaBH4 concentration, flow rates o...
Determination of SARA fractions of crude oils by NMR technique
Kök, Mustafa Verşan; Nurgaliev, Danis K. (Elsevier BV, 2019-08-01)
In this research, four different crude oils from Tatarstan oil fields with wide range of API gravities (from 16.6 to 32.5 degrees API) were used for hydrogen and carbon nuclear magnetic resonance spectroscopy (H NMR and C NMR) determinations. The hydrogen and carbon aromaticity factors were calculated by using the results of H NMR and C NMR spectroscopy results. The results show that the aromaticity factors were high for heavy crude oils. For predicting SARA fractions, the correlations were developed as a f...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
O. Cankur, N. Ertas, and O. Y. Ataman, “Determination of bismuth using on-line preconcentration by trapping on resistively heated W coil and hydride generation atomic absorption spectrometry,”
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
, pp. 603–609, 2002, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/30603.