Comparison of low and high Pd loadings on CNTs via supercritical fluid deposition as hydrogen storage materials

2018-04-28
Erünal, Ebru
Ulusal, Fatma
Odabaşı, Selda
Aslan, Mustafa Yasin
Güzel, Bilgehan
Üner, Deniz

Suggestions

Comparison of Fully Coupled and DecoupledModeling Results of Graphite Ablation In Hypersonic Flows
Onay, Oğuz; Eyi, Sinan (2019-09-20)
A thermochemical ablation modeling tool is developed for graphite material in air for reactive hypersonic flows. Multi-species and axisymmetric Navier-Stokes equations are solved for the flow field analysis. Arrhennius type of relations are utilized for finite rate reactions and chemical equilibrium is assumed on the eroding wall of graphite material. Total of thirteen species are included in the analysis in which eight of them are the products of the graphitic material ablation. Flow field, surface thermoc...
Comparison of thermal sterilization and high hydrostatic pressure-HHP on furan formation, microbial and nutritional quality in commercial baby foods
Kültür, Gülçin; Alpas, Hami; Department of Food Engineering (2013)
Furan, which is a lipophilic contaminant and formed during heating process in foods, has been pointed out as a danger in baby foods since it has been classified as “possibly carcinogenic to human” by IARC (International Agency for Research on Cancer). Hence, a great concern has been addressed to the analysis of this substance in baby foods. This study aims to prove that sterilization of baby foods is possible by high hydrostatic pressure (HHP) without allowing the formation of furan. Firstly, HHP treatments...
Comparison of in vitro cytotoxicity and genotoxicity of MMA-based polymeric materials and various metallic materials
GÜLÇE İZ, SULTAN; Gurhan, Saime Ismet Deliloglu; Sen, Bilge Hakan; Endoğan Tanır, Tuğba; Hasırcı, Nesrin (2010-12-01)
Aim: To determine the in vitro cytotoxicity and genotoxicity of some polymeric and metallic implant materials used as base materials in dentistry, based on ISO (International Organization for Standardization) and OECD (Organization for Economic Co-Operation and Development) test protocols.
Comparison of Performances of Microwave and Conventionally Heated Reactors in Sorption Enhanced Reforming of Ethanol over Ni Incorporated Meesoporous Catalysts
Sarıyer, Merve; Sezgi, Naime Aslı (null; 2018-10-28)
Comparison of the shear strength of statically and dynamically compacted clays
Gün, K Fırat; Mirata, Türker; Department of Civil Engineering (1997)
Citation Formats
E. Erünal, F. Ulusal, S. Odabaşı, M. Y. Aslan, B. Güzel, and D. Üner, “Comparison of low and high Pd loadings on CNTs via supercritical fluid deposition as hydrogen storage materials,” Çukurova Universitesi , Adana, 2018, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/70625.