PERFORMANCE BASED LIMIT STATES FOR INFILL WALLS IN RC FRAMES

2018-06-18

Suggestions

Performance Based Design of Seismic Isolated Bridges in Near-Fault Zones Using Elastic-Gap Devices
Dicleli, Murat (2009-06-28)
This paper investigates the efficiency of using elastic-gap devices (EGDs) to improve the performance of seismic-isolated bridges (SIBs) in near-fault (NF) zones. The EDG is intended to function at two performance levels under service and maximum considered design level (SDL and MCDL) NF earthquakes to reduce isolator displacements (IDs) while keeping the substructure forces (SFs) at reasonable levels. Analyses of structural models of bridges with EGDs revealed that providing EGD is beneficial for decreasin...
Performance Comparison of Passive Series R and Shunt R-C Damped LCL Filter for Grid-Connected Inverters
Temiz, Hakan; Demirok, Erhan; Keysan, Ozan; Türkay, A; Çetinkaya, B (null; 2018-09-27)
: LCL filters are widely used in distributed power-generation systems to attenuate high-frequency harmonics caused by pulse-width modulation switching of grid-connected inverters. A resonance occurs due to the series-connected reactive components. In order to damp resonance effects, active and passive damping methods are used. Lower switching frequencies are typically preferred to decrease switching power losses with high-power applications. Thus, control bandwidth of the system is limited and implementatio...
Performance comparison of passive series R and shunt R-C damped LCL filter for grid-connected inverters
Temiz, Hakan; Demirok, Erhan; Keysan, Ozan; Turkay, Ali; Cetinkaya, Burak (2019-07-01)
LCL filters are widely used in distributed power-generation systems to attenuate high-frequency harmonics caused by pulse-width modulation switching of grid-connected inverters. A resonance occurs due to the series-connected reactive components. In order to damp resonance effects, active and passive damping methods are used. Lower switching frequencies are typically preferred to decrease switching power losses with high-power applications. Thus, control bandwidth of the system is limited and implementation ...
Performance enhancement and comparison of discrete time current regulators for parallel active filters
Ozkaya, Hasan; Senturk, Osman Selcuk; Hava, Ahmet Masum (2007-09-05)
Discrete time linear and hysteresis current regulators (CR) for three-phase parallel active filters (PAF) are reviewed and evaluated. A novel discrete time hysteresis current regulation method with current oversampling and flexible PWM release capability, DHCR3, which has superior overall performance and simple implementation (no additional hardware) is proposed. Switching ripple filters (SRF) suitable for each CR type are designed. A DSP controlled PAF is designed and built for a three-phase 10 kW diode re...
Performance based design of seismic isolated bridges in cold climates using multi directional torsional hysteretic damper and lubricated flat sliding spherical bearings
Dicleli, Murat (null; 2019-07-06)
Citation Formats
İ. O. Demirel, A. Yakut, B. Binici, and E. Canbay, “PERFORMANCE BASED LIMIT STATES FOR INFILL WALLS IN RC FRAMES,” 2018, Accessed: 00, 2021. [Online]. Available: http://www.16ecee.org/.