An Adaptive Converter for Current Neural Stimulators Achieving up to 79% Power Dissipation Reduction

2021-01-01
Koc, Mert
Chamanian, Salar
Yigit, Halil Andac
ULUŞAN, HASAN
Külah, Haluk
Power consumption in neural stimulation devices such as cochlear implants, or retinal implants, is an important issue. These devices operate in volume constrained conditions and therefore have a drawback in terms of energy storage. This means that the converters used for the necessary voltage compliance in these devices must be as efficient as possible. This work describes a system implementing an adaptive converter together with a constant current stimulator. The adaptive converter utilizes a three-stage charge pump with a total of 600 pF on-chip MIM capacitors occupying 1 mm(2) area. Fed from a single supply, it can provide 3.3/6/9/12 V output with varying load current between 100 to 900 mu A. The converter changes its output, i.e., stimulator supply voltage depending on the digitally controlled stimulation current. This eliminates the unused voltage headroom and provides more efficient operation compared to constant voltage converters. In addition, reduced number of bulky off-chip flying capacitors make the converter appealing for volume constricted stimulators, such as fully implantable cochlear implants. An H-bridge was used to create the stimulation current, enabling single supply operation. Operational stage number and pulse frequency modulation was utilized to configure the output. In-vitro tests show a decrease of up to 79% in the power dissipation of the constant current stimulator compared to its constant 12 V operation.
IEEE International Symposium on Circuits and Systems (IEEE ISCAS)

Suggestions

An Integrated imaging sensor for rare cell detection applications
Altıner, Çağlar; Akın, Tayfun; Eminoğlu, Selim; Department of Micro and Nanotechnology (2012)
Cell detection using image sensors is a novel and promising technique that can be used for diagnostic applications in medicine. For this purpose, cell detection studies with shadowing method are performed with yeast cells (Saccharomyces cerevisiae) using an 32×32 complementary metal oxide semiconductor (CMOS) image sensor that is sensitive to optical illumination. Cells that are placed zero distance from the sensor surface are detected using the image sensor which is illuminated with four fixed leds to main...
A Vibration Based Mechanical IR Detector and an IR Imaging Method Using The Same
Azgın, Kıvanç (Dünya Fikri Mülkiyet Teşkilatı, 2013)
The invention relates to a vibration based mechanical IR detector having one or more than one resonating pixel structure and an IR imaging method for measuring incoming IR radiation by means of mechanical resonance of the resonating pixels.
An ultra-wide band low-SAR flexible metasurface-enabled antenna for WBAN applications
Yalduz, Husnu; Koc, Burak; Kuzu, Lokman; TÜRKMEN, MUSTAFA (Springer Science and Business Media LLC, 2019-08-09)
In this study, an ultra-wideband low-specific absorption rate (SAR) flexible metasurface-enabled wearable antenna is proposed for wireless body area network applications. The antenna and metamaterial (MM) structure were designed and analyzed using a commercial electromagnetic simulation software program which uses a finite integration technique solver. The antenna is designed and fabricated on a jeans textile substrate in the size of 58 x 80 x 1 mm(3). Moreover, MM reflector was designed on a felt textile s...
An Improved Receiver for Harmonic Motion Microwave Doppler Imaging
Soydan, Damla Alptekin; Irgin, Umit; Top, Can Baris; Gençer, Nevzat Güneri (2020-03-01)
© 2020 EurAAP.Harmonic motion microwave Doppler imaging is a novel imaging modality that combines focused ultrasound and radar techniques to obtain data based on mechanical and electrical properties of the tissue. In previous experimental studies, the Doppler component of the scattered signal is sensed and used to create 2D images of a tumor inside a homogeneous fat phantom. Due to the drawbacks of the receiver configuration, scanning time was high, the signal-to-noise ratio was low, and the multi-frequency...
A Readout circuit for resonant MEMS temperature sensors
Asadi, Hamed; Akın, Tayfun; Azgın, Kıvanç; Department of Electrical and Electronics Engineering (2016)
High precision is the dominant advantage that resonant sensors have over other types of analog sensors (sensors with a subsequent analog-to-digital converter). The resolution of these precise sensors is determined by both frequency resolution and sensitivity of the sensor. The sensitivity is highly related to the sensitivity of the MEMS resonator. However, the frequency resolution is dominantly defined by the closed-loop circuitry if noise contribution of the resonator is assumed to be smaller than that of ...
Citation Formats
M. Koc, S. Chamanian, H. A. Yigit, H. ULUŞAN, and H. Külah, “An Adaptive Converter for Current Neural Stimulators Achieving up to 79% Power Dissipation Reduction,” presented at the IEEE International Symposium on Circuits and Systems (IEEE ISCAS), Daegu, Güney Kore, 2021, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/93791.