Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Effects of Torso Inhomogeneities on Spontaneous PVC Localization in Potential and Dipole-Based Methods
Date
2023-01-01
Author
Rasoolzadeh, Nika
Ondrusova, Beata
Serinağaoğlu Doğrusöz, Yeşim
Svehlikov, Jana
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
67
views
0
downloads
Cite This
The use of electrocardiographic imaging for the localization of the undesired premature ventricular contraction needs a torso volume conductor definition. This study aims to investigate the specific effect of lung and blood cavity inhomogeneities on the performance of inverse localization. Two source models were assumed for the inverse solution applied to clinical data; potential on the closed epicardial-endocardial surface and a single dipole. The results showed that the potential-based solution performed better if the presence of at least blood cavities was assumed, while the dipole-based solution was not significantly influenced by the presence of inhomogeneities. The importance of the inhomogeneities in the torso model for the inverse solution also depends on the used model of the equivalent heart generator.
Subject Keywords
Electrocardiographic Imaging (ECGI)
,
Premature Ventricular Contraction (PVC)
,
Torso Inhomogeneities
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85164983448&origin=inward
https://hdl.handle.net/11511/104937
DOI
https://doi.org/10.23919/measurement59122.2023.10164347
Conference Name
14th International Conference on Measurement, MEASUREMENT 2023
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
N. Rasoolzadeh, B. Ondrusova, Y. Serinağaoğlu Doğrusöz, and J. Svehlikov, “Effects of Torso Inhomogeneities on Spontaneous PVC Localization in Potential and Dipole-Based Methods,” presented at the 14th International Conference on Measurement, MEASUREMENT 2023, Smolenice Castle, Slovakya, 2023, Accessed: 00, 2023. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85164983448&origin=inward.