Development and validation of a digital twin of the human lower jaw under impact loading by using non-linear finite element analyses

2023-12-01
Demir, Osman
Uslan, Ibrahim
Büyük, Murat
SALAMCI, METİN UYMAZ
Mandibular fractures are one of the most frequently observed injuries within craniofacial region mostly due to tumor-related problems and traumatic events, often related to non-linear effects like impact loading. Therefore, a validated digital twin of the mandible is required to develop the best possible patient-specific treatment. However, there is a need to obtain a fully compatible numerical model that can reflect the patients’ characteristics, be available and accessible quickly, require an acceptable level of modeling efforts and knowledge to provide accurate, robust and fast results at the same time under highly non-linear effects. In this study, a validated simulation methodology is suggested to develop a digital twin of mandible, capable of predicting the non-linear response of the biomechanical system under impact loading, which then can be utilized to design treatment strategies even for multiple fractures of the mandibular system. Using Computed Tomography data containing cranial (skull) images of a patient, a 3-dimensional mandibular model, which consists cortical and cancellous bones, disks and fossa is obtained with high accuracy that is compatible with anatomical boundaries. A Finite Element Model (FEM) of the biomechanical system is then developed for a three-level validation procedure including (A) modal analysis, (B) dynamic loading and (C) impact loading. For the modal analysis stage: Free-free vibration modes and frequencies of the system are validated against cadaver test results. For the dynamic loading stage: Two different regions of the mandible are loaded, and maximum stress levels of the system are validated against finite element analyses (FEA) results, where the first loading condition (i) transfers a 2000 N force acting on the symphysis region and, the second loading condition (ii) transfers a 2000 N force acting on the left body region. In both cases, equivalent muscle forces dependent on time are applied. For the impact loading stage: Thirteen different human mandibular models with various tooth deficiencies are used under the effects of traumatic impact forces that are generated by using an impact hammer with different initial velocities to transfer the impulse and momentum, where contact forces and fracture patterns are validated against cadaver tests. Five different anatomical regions are selected as the impact site. The results of the analyzes (modal, dynamic and impact) performed to validate the digital twin model are compared with the similar FEA and cadaver test results published in the literature and the results are found to be compatible. It has been evaluated that the digital twin model and numerical models are quite realistic and perform well in terms of predicting the biomechanical behavior of the mandible. The three-level validation methodology that is suggested in this research by utilizing non-linear FEA has provided a reliable road map to develop a digital twin of a biomechanical system with enough confidence that it can be utilized for similar structures to offer patient-specific treatments and can help develop custom or tailor-made implants or prosthesis for best compliance with the patient even considering the most catastrophic effects of impact related trauma.
Journal of the Mechanical Behavior of Biomedical Materials
Citation Formats
O. Demir, I. Uslan, M. Büyük, and M. U. SALAMCI, “Development and validation of a digital twin of the human lower jaw under impact loading by using non-linear finite element analyses,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 148, pp. 0–0, 2023, Accessed: 00, 2023. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85175268083&origin=inward.