Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Seismic performance of a precast concrete conection used in single storey buildings
Download
035672.pdf
Date
1994
Author
Dönmez, Cemalettin
Metadata
Show full item record
Item Usage Stats
100
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/11387
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Seismic performance of an improved precast concrete connection used in signle storey buildings
Yılmaz, Murat Kuzey; Tankut, Tuğrul; Department of Civil Engineering (1997)
Seismic performance of an improved precast concrete connection used in single buildings
Demiralp, Onder; Tankut, Tuğrul; Department of Civil Engineering (1996)
Seismic performance of a precast concrete connection used in Turkey
Korkmaz, Hasan Hüsnü; Tankut, Tuğrul; Department of Civil Engineering (1998)
Seismic performance of gravity-load designed concrete frames infilled with low-strength masonry
Siddiqui, Umair A.; Sucuoğlu, Haluk; Yakut, Ahmet (2015-01-01)
This study compares the seismic performances of two reinforced concrete frame specimens tested by the pseudo-dynamic procedure. The pair of 3-storey, 3-bay frames specimens are constructed with typical characteristics of older construction which is lacking seismic design. One of the specimens is a bare frame while the other is infilled with low-strength autoclave aerated concrete (AAC) block masonry. The focus of this study is to investigate the influence of low strength masonry infill walls on the seismic ...
Seismic behavior of autoclaved aerated concrete low rise buildings with reinforced wall panels
Gökmen, Furkan; Binici, Barış; Canbay, Erdem (Springer Science and Business Media LLC, 2019-07-01)
Reinforced Autoclaved Aerated Concrete (AAC) wall panels are more commonly used to construct load-bearing walls in low-rise prefabricated buildings located in seismic zones. In the scope of this study, the seismic response of buildings constructed with reinforced AAC wall panels was investigated. To this end, an in situ test was conducted on a two-story test building under reversed cyclic displacement excursions. It was determined that the test building could carry a lateral load of 60% more than its weight...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
C. Dönmez, “Seismic performance of a precast concrete conection used in single storey buildings,” Middle East Technical University, 1994.