Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Graduate School of Informatics, Software
Item Usage Stats
Browse
By Issue Date
Authors
Titles
Subjects
Search within this collection:
ui-button
Filters
Entity Type
Publication (2)
Has File(s)
No (2)
Author
Abran, Alain (1)
Appelrath, H. -Juergen (1)
Desharnais, Jean-Marc (1)
Dikici, Pinar Efe (1)
Eichelberg, Marco (1)
P
N
Subject
Adverse drug event (ADE) (1)
Adverse drug reaction (ADR) (1)
COSMIC (1)
Electronic health record (EHR) (1)
FPA (1)
P
N
Date Issued
2009 - 2009 (1)
2010 - 2014 (1)
P
N
Item Type
P
N
Recent Submissions
F
P
1
N
E
Adverse Drug Event Notification System Reusing clinical patient data for semi-automatic ADE detection
Krahn, Tobias; Eichelberg, Marco; Gudenkauf, Stefan; Erturkmen, Gokce B. Laleci; Appelrath, H. -Juergen;( Abstracts: Adverse drug events (ADEs) are common, costly and a public health issue. Today, their detection relies on medical chart review and spontaneous reports, but this is known to be rather ineffective. Along with the increasing availability of clinical patient data in electronic health records (EHRs), a computer-based ADE detection has a tremendous potential to contribute to patient safety. Current ADE detection systems are very specific, usually built directly on top of clinical information systems through proprietary interfaces. Thus, it is not possible to run different ADE detection tools on top of already existing systems in an ad-hoc manner. The European project "SALUS" aims at providing the necessary infrastructure and toolset for accessing and analyzing clinical patient data of heterogeneous clinical information systems. This paper highlights the SALUS ADE notification system as the key tool to enable a semi-automatic ADE detection and notification. In contrast to previous work, the ADE notification system is not restricted to a specific clinical environment. It can be run on different clinical data models with different levels of data quality. The system is equipped with innovative features, building up an intelligent, comprehensive ADE detection and notification system that promises a profound impact in the domain of computer-based ADE detection.; 2014-05-29)
Adverse drug events (ADEs) are common, costly and a public health issue. Today, their detection relies on medical chart review and spontaneous reports, but this is known to be rather ineffective. Along with the increasing ...
Functional Size of a Real-Time System
Desharnais, Jean-Marc; Abran, Alain; Dikici, Pinar Efe; Ilis, Mert Can; Karaca, Irfan Nuri;( Abstracts: This paper presents a case study on the implementation of IFPUG FPA and COSMIC software measurement methods for a small real-time system. The two methods were applied separately to measure the functional size of the same software. The main objective of this paper is to explore, through a case study, the issue of the measurement adequacy of each measurement method to capture the functional size of real-time software. For the practitioners, the real issue is that such a 'number' represent adequately the functional size. This number should take into consideration the particularities of specific real-time software and be sensitive to small variations of functionality.; 2009-11-06)
This paper presents a case study on the implementation of IFPUG FPA and COSMIC software measurement methods for a small real-time system. The two methods were applied separately to measure the functional size of the same s...
F
P
1
N
E
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX