Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
A Current Source Converter-Based Active Power Filter for Mitigation of Harmonics at the Interface of Distribution and Transmission Systems
Date
2012-07-01
Author
Terciyanli, Alper
Avci, Tulay
Yilmaz, Ilker
Ermis, Cezmi
Kose, Kemal Nadir
Acik, Adnan
Kalaycioglu, Alper Sabri
Akkaya, Yener
Cadirci, Isik
Ermiş, Muammer
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
242
views
0
downloads
Cite This
A medium-power current source converter (CSC)-based shunt active power filter (APF) system is designed and implemented to suppress the amplification of low-order harmonics at the medium-voltage (MV) interface bus between the distribution and transmission systems, owing to the presence of large shunt capacitor banks installed only for reactive power compensation. Four CSC-based APF modules designed at 1.0 kV are operated in parallel and connected to the 31.5-kV MV bus via a specially designed coupling transformer. In each APF module, a specially designed LC-type input filter eliminates the switching ripples, and active damping method embedded into the control software suppresses harmonic frequencies around the corner frequency of the input filter. The resulting system can operate at relatively high frequencies in the range from 2.0 to 3.0 kHz, depending upon which selected harmonics among 5th, 7th, 11th, and 13th are to be eliminated. Furthermore, in order to reduce the installed capacity of CSCs, selective harmonic amplification method is applied to the APF system described in the paper. MV APF system has been built as a mobile system for temporary connection to a problematic MV interface bus until a permanent solution is found for that location in the distribution system.
Subject Keywords
Active filters
,
Harmonic distortion
,
Power quality (PQ)
,
Pulsewidth modulated power converters
,
Resonance
URI
https://hdl.handle.net/11511/30219
Journal
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
DOI
https://doi.org/10.1109/tia.2012.2200009
Collections
Graduate School of Natural and Applied Sciences, Article
Suggestions
OpenMETU
Core
A Selective Harmonic Amplification Method for Reduction of kVA Rating of Current Source Converters in Shunt Active Power Filters
Terciyanli, Alper; Ermiş, Muammer; Cadirci, Isik (2011-01-01)
This paper describes a new approach to the design of current-source converter (CSC)-based shunt active power filters (APFs) to reduce the converter kilovolt-ampere rating considerably. This design approach is called the selective harmonic amplification method (SHAM), and is based on the amplification of some selected harmonic current components of CSC by the ac-side filter, and the CSC control system specifically designed for this purpose. The proposed SHAM has been implemented on a CSC-based APF for the el...
High Performance Harmonic Isolation By Means of The Single-phase Series Active Filter Employing The Waveform Reconstruction Method
Senturk, Osman S.; Hava, Ahmet Masum (2009-09-24)
This paper proposes the Waveform Reconstruction Method (WRM), which is utilized in the single-phase Series Active Filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line current sampling delay reduction method (SDRM), a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous re...
A unity-power-factor buck-type PWM rectifier for medium/high-power DC motor drive applications
Bilgin, HF; Kose, KN; Zenginobuz, G; Ermiş, Muammer; Nalcaci, E; Cadirci, I; Kose, H (2002-09-01)
This paper describes the application of a single-stage unity-power-factor buck-type pulsewidth modulation (PWM) rectifier to medium- and high-power variable-speed dc motor drives. The advantages of the developed system are low harmonic distortion in ac supply currents (complying with IEEE Std. 519 and IEC 555), nearly unity power factor over a wide operating shaft speed range, and nearly level armature current and voltage waveforms. These properties of output voltage and current quantities of the converter ...
High Performance Harmonic Isolation and Load Voltage Regulation of the Three-Phase Series Active Filter Utilizing the Waveform Reconstruction Method
Sentuerk, Osman S.; Hava, Ahmet Masum (2008-10-09)
This paper develops the Waveform Reconstruction Method (WRM) for high accuracy and bandwidth signal decomposition of voltage harmonic type (V-type) three-phase diode rectifier load voltage into its harmonic and fundamental components, which are utilized in the Series Active Filter (SAF) control algorithms. The SAF compensated system utilizing WRM provides high performance load harmonic voltage isolation and load voltage regulation at steady-state and during transients compared to the system utilizing the sy...
Design and implementation of a voltage source converter based statcom for reactive power compensation and harmonic filtering
Çetin, Alper; Ermiş, Muammer; Department of Electrical and Electronics Engineering (2007)
In this thesis, design and implementation of a distribution-type, voltage source converter (VSC) based static synchronous compensator (D-STATCOM) having the simplest converter and coupling transformer topologies have been carried out. The VSC STATCOM is composed of a +/- 750 kVAr full-bridge VSC employing selective harmonic elimination technique, a low-pass input filter, and a /Y connected coupling transformer for connection to medium voltage bus. The power stage of VSC based STATCOM is composed of water-co...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. Terciyanli et al., “A Current Source Converter-Based Active Power Filter for Mitigation of Harmonics at the Interface of Distribution and Transmission Systems,”
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
, pp. 1374–1386, 2012, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/30219.