Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Optimization of bread baking in a halogen lamp-microwave combination oven by response surface methodology
Date
2004-09-01
Author
Demirekler, P
Şümnü, Servet Gülüm
Şahin, Serpil
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
232
views
0
downloads
Cite This
The main objective of this study was to optimize the baking conditions of bread in a halogen lamp-microwave combination oven. Independent variables were the baking time (4, 4.5, 5, 5.5, and 6 min), the power of the microwaves (20, 30, 40, 50, and 60%), and the power of the upper and lower halogen lamps (40, 50, 60, 70, and 80%). The quality parameters measured were the weight loss, the color, the specific volume, the porosity, and the texture profile of the breads. For the optimization, the response surface methodology was used. Baking time, upper halogen lamp power, and microwave power were found to be significant in affecting most of the quality parameters. On the other hand, the lower halogen lamp power was found to be an insignificant factor. The optimum baking conditions in the halogen lamp-microwave combination oven were determined as 5 min of baking time at 70% upper halogen lamp power, 50% lower halogen lamp power, and 20% microwave power. Breads baked at the optimum condition had comparable quality with conventionally baked ones. When the halogen lamp-microwave combination oven was used, the conventional baking time of breads was reduced by 60%.
Subject Keywords
Biotechnology
,
Food Science
,
Industrial and Manufacturing Engineering
,
Biochemistry
,
General Chemistry
URI
https://hdl.handle.net/11511/37316
Journal
EUROPEAN FOOD RESEARCH AND TECHNOLOGY
DOI
https://doi.org/10.1007/s00217-004-0969-3
Collections
Department of Food Engineering, Article
Suggestions
OpenMETU
Core
Optimization of halogen lamp-microwave combination baking of cakes: a response surface methodology study
Sevimli, KM; Şümnü, Servet Gülüm; Şahin, Serpil (Springer Science and Business Media LLC, 2005-07-01)
The main objective of this study was to optimize processing conditions during halogen lamp-microwave combination baking of cake by using response surface methodology. The independent variables were the power of the upper halogen lamp (50, 60, and 70%), the power of the lower halogen lamp (50, 60, and 70%), the power of the microwaves (30, 40, and 50%), and the baking time (4, 5, and 6 min). Weight loss, specific volume, color, and the texture profile of the cakes were determined. The upper halogen lamp powe...
Production of bread crumbs by infrared-assisted microwave drying
Tireki, S; Şümnü, Servet Gülüm; Esin, A (Springer Science and Business Media LLC, 2006-01-01)
This study is aimed to investigate the possibility of using infrared-assisted microwave drying for production of bread crumbs and to determine drying conditions in halogen lamp-microwave combination oven to produce bread crumbs with the highest quality. Bread crumb dough were dried from about 40.9 to 8% moisture content by conventional, microwave, infrared and infrared-assisted microwave drying separately and in combinations. Halogen lamp and microwave power levels of 30, 50 and 70% were used. Percent reduc...
A study on the effects of different gums on dielectric properties and quality of breads baked in infrared-microwave combination oven
Keskin, Semin Ozge; Şümnü, Servet Gülüm; Şahin, Serpil (Springer Science and Business Media LLC, 2007-01-01)
In this study, the effects of different gums on dielectric properties of doughs and breads baked in infrared-microwave combination oven were investigated. In addition, the quality parameters of breads formulated with different gums baked in infrared-microwave combination oven were determined. The gums used were xanthan, guar, xanthan-guar blend and kappa-carrageenan. The gums were added to the formulation at 0.5% concentration. The dielectric properties and quality parameters of breads baked in infrared-mic...
Optimisation of formulations and infrared-microwave combination baking conditions of chestnut-rice breads
Demirkesen, Ilkem; Şümnü, Servet Gülüm; Şahin, Serpil; Uysal, Nalan (Wiley, 2011-09-01)
The main objective of this study was to design gluten-free breads containing chestnut and rice flour and xanthan-guar gum blend to be baked in infrared-microwave combination oven. Response surface methodology (RSM) was used to optimise gluten-free bread formulations and processing conditions. Weight loss, firmness, specific volume and colour change of the breads were determined. Rice flour mixed with different proportions of chestnut flour and different emulsifier contents were used to prepare breads. The g...
Optimization of roasting conditions of hazelnuts in microwave assisted ovens
Uysal, Nalan; Şümnü, Servet Gülüm; Department of Food Engineering (2009)
The main objective of this study was to optimize the roasting conditions of hazelnuts in microwave-infrared and microwave-convective heating combination ovens by using response surface methodology. It was also aimed to construct regression models for the prediction of quality parameters of hazelnuts as a function of processing conditions. The independent variables were microwave power (10, 30, 50, 70 and 90%), upper-lower infrared power (10, 30, 50, 70 and 90%) and roasting time (2, 3, 4, 5 and 6 min) for m...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
P. Demirekler, S. G. Şümnü, and S. Şahin, “Optimization of bread baking in a halogen lamp-microwave combination oven by response surface methodology,”
EUROPEAN FOOD RESEARCH AND TECHNOLOGY
, pp. 341–347, 2004, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/37316.