Use of a simple transient extension chamber with ETV-ICPMS: quantitative analysis and matrix effects

2003-01-01
The transient extension (TEx) chamber was developed to provide a simple means of lengthening an electrothermal vaporizer (ETV) signal for the purpose of obtaining a full mass scan from a single ETV firing with inductively coupled plasma mass spectrometry (ICPMS) detection. The TEx chamber was used for quantitative analysis of natural water (NIST SRM 1640). Quantitative analysis was done for Co, Be, Pb, Sb and Cd. Detection limits for the five elements tested with the TEx chamber were in the 1-10 mug L-1 range when monitoring 256 masses during a single ETV firing. In general, there was no significant change in the analyte signal using palladium, sodium chloride or magnesium nitrate modifiers when comparing results with and without the TEx chamber.
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY

Suggestions

Melatonin induces opposite effects on order and dynamics of anionic DPPG model membranes
Sahin, Ipek; Severcan, Feride; Kazanci, Nadide (Elsevier BV, 2007-05-27)
The temperature and concentration induced effects of melatonin on anionic dipalmitoyl phosphatidylglycerol (DPPG) multilamellar liposomes (MLVs) were investigated by using Fourier transform infrared (FTIR) spectroscopy and differential scanning calorimetry (DSC). The results show that melatonin does not perturb the phase transition profile, while a decrease in the main transition temperature (T-m) is noticed at high melatonin concentrations (15, 24 and 30 mol Low concentrations of melatonin (3, 6 and 9 mol ...
Use of multi-walled carbon nanotubes in matrix solid phase dispersion extraction combined with gas chromatography
Njie, Njaw; Aygün, Rüveyde Sezer; Department of Chemistry (2008)
The use of Multi-Walled Carbon Nanotubes (MWCNT) as solid sorbent in Matrix Solid-Phase Dispersion (MSPD) extraction and preconcentration method was presented to determine some commonly used organophosphorus insecticides/OPIs in honey samples using a Gas Chromatography Flame Ionization Detector (GC-FID). OPIs are poisonous compounds used to kill insects and rodents by affecting their nervous system. The limit of detections obtained after MSPD extraction were 7.0 ng/g for Malathion, Malaoxon and Fenitrothion...
Monte Carlo simulation of transport from an electrothermal vaporizer
Holcombe, James A.; Ertaş, Gülay (Elsevier BV, 2006-06-01)
Monte Carlo simulations were developed to elucidate the time and spatial distribution of analyte during the transport process from an electrothermal vaporizer to an inductively coupled plasma. A time-of-flight mass spectrometer was employed to collect experimental data that was compared with the simulated transient signals. Consideration was given to analyte transport as gaseous species as well as aerosol particles. In the case of aerosols, the simulation assumed formation of 5 nm particles and used the Ein...
Immobilization studies utilizing solid supports for the determination of fructose by dansylaminophenyl boronic acid (DAPB acid) and chromate by diphenylcarbazide (DPC)
Bulut, Mukadder; Volkan, Mürvet; Department of Chemistry (2006)
Immobilization of fluorescent chemosensors and chromogenic reagents on solid supports for developing optical sensors result in improved analytical performance characteristics such as continuous read-out, increased sensitivity, lower reagent consumption and possibility of using the sensor in solvents where the free molecule displays low solubility. The aim of this study is to immobilize dansylaminophenyl boronic acid (DAPB acid) and diphenylcarbazide (DPC) into various solid supports for the determination of...
Modeling of dispersion in a polymeric chromatographic monolith
Koku, Harun; Schure, Mark R.; Lenhoff, Abraham M. (Elsevier BV, 2012-05-11)
Dispersion in a commercial polymeric monolith was simulated on a sample geometry obtained by direct imaging using high-resolution electron microscopy. A parallelized random walk algorithm, implemented using a velocity field obtained previously by the lattice-Boltzmann method, was used to model mass transfer. Both point particles and probes of finite size were studied. Dispersion simulations with point particles using periodic boundaries resulted in plate heights that varied almost linearly with flow rate, a...
Citation Formats
G. Ertaş, “Use of a simple transient extension chamber with ETV-ICPMS: quantitative analysis and matrix effects,” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, pp. 878–883, 2003, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/40988.