Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Microwave, infrared and infrared-microwave combination baking of cakes
Date
2005-11-01
Author
Şümnü, Servet Gülüm
Şahin, Serpil
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
194
views
0
downloads
Cite This
The objective of the study was to compare the quality of cakes during baking in microwave, infrared (IR) and IR-microwave combination ovens. Quality parameters evaluated were weight loss, specific volume, firmness and colour of cakes. As control, conventionally baked cakes were used. Cakes baked in a microwave oven had the lowest quality. It was possible to achieve surface colour formation in cakes by IR and IR-microwave combination baking. IR-microwave combination baking reduced weight loss and firmness while it increased the volume of microwave baked breads. Halogen lamp-microwave combination oven produced cakes having similar firmness and colour values with conventionally baked ones. The best conditions for baking of cakes in IR-microwave combination oven was 5 min at 70% halogen lamp and at 50% microwave power levels. When an IR-microwave combination oven was used at this condition conventional baking time of cakes was reduced by about 75%.
Subject Keywords
Baking
,
Cake
,
İnfrared
,
Microwaves
,
Physical properties
URI
https://hdl.handle.net/11511/47946
Journal
JOURNAL OF FOOD ENGINEERING
DOI
https://doi.org/10.1016/j.jfoodeng.2004.10.027
Collections
Department of Food Engineering, Article
Suggestions
OpenMETU
Core
Assessment of proofing of bread dough in the microwave oven
Ozmutlu, O; Şümnü, Servet Gülüm; Şahin, Serpil (2001-01-01)
The effects of different proofing times in the microwave oven on the quality of microwave baked breads were investigated. The proofing height of the dough, specific volume and the firmness of the breads were found to be dependent on proofing time. When emulsifiers were added, the optimum proofing condition in the microwave oven was found to be 6 minutes at 10% power. The effects of different emulsifiers on the properties of the dough and, the volume and the firmness of the microwave-baked breads were compar...
THE EFFECT OF DIFFERENT FORMULATIONS ON PHYSICAL PROPERTIES OF CAKES BAKED WITH MICROWAVE AND NEAR INFRARED-MICROWAVE COMBINATIONS
Sakiyan, Ozge; Şümnü, Servet Gülüm; Şahin, Serpil; Meda, Venkatesh (2007-01-01)
The aim of this study was to determine the effect of different formulations on color and textural characteristics of different cakes during baking in microwave and near infrared-microwave combination ovens. For comparison, cakes were also baked in conventional ovens. Color and hardness for both types of baking schemes were found to be dependent on formulation. Cakes containing Simplesse (TM), a fat replacer consisting mostly of whey protein, baked in microwave and near infrared-microwave combination ovens w...
Optimization of Baking of Rice Cakes in Infrared-Microwave Combination Oven by Response Surface Methodology
Turabi, Elif; Şümnü, Servet Gülüm; Şahin, Serpil (2008-03-01)
In this study, response surface methodology was used to design gluten-free cakes made from rice flour to be baked in infrared-microwave combination oven. Two types of cake formulations containing different types of gums were used in the experiments, which were xanthan gum and xanthan-guar gum blend. The independent variables were emulsifier content (0, 3, and 6% of flour weight), upper halogen lamp power (50, 60, and 70%), and baking time (7, 7.5, and 8 min). Specific volume, surface color change, firmness ...
Temperature and weight loss profiles of model cakes baked in the microwave oven
Şümnü, Servet Gülüm; Bayindirli, L (1999-01-01)
Model cake systems were formulated with wheat and rice starches at hydration levels of 112.5% and 137.5% (flour weight basis) and baked in a microwave oven at power levels of 80% and 100%. Temperature profiles and weight loss profiles of the cakes baked in the microwave oven were compared with those of the cakes baked conventionally. One cake was baked at a time, and three replications of each treatment were used. Center and edge temperatures of microwave cakes increased significantly with increasing moistu...
Bread baking in halogen lamp-microwave combination oven
Keskin, SO; Şümnü, Servet Gülüm; Şahin, Serpil (Elsevier BV, 2004-01-01)
The main objective of the study was to compare the effects of halogen lamp-microwave combination baking on quality of breads with other baking methods (conventional, microwave and halogen lamp baking). It was also aimed to improve the quality of microwave baked breads by using combination oven. Weight loss, specific volume, firmness and color of the breads were measured as quality parameters. Halogen lamp-microwave combination oven reduced the conventional baking time of breads by about 75%. Microwave heati...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
S. G. Şümnü and S. Şahin, “Microwave, infrared and infrared-microwave combination baking of cakes,”
JOURNAL OF FOOD ENGINEERING
, pp. 150–155, 2005, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/47946.