Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Sensitivity of EEG and MEG measurements to tissue conductivity
Date
2004-03-07
Author
Gençer, Nevzat Güneri
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
206
views
0
downloads
Cite This
Monitoring the electrical activity inside the human brain using electrical and magnetic field measurements requires a mathematical head model. Using this model the potential distribution in the head and magnetic fields outside the head are computed for a given source distribution. This is called the forward problem of the electro-magnetic source imaging. Accurate representation of the source distribution requires a realistic geometry and an accurate conductivity model. Deviation from the actual head is one of the reasons for the localization errors. In this study, the mathematical basis for the sensitivity of voltage and magnetic field measurements to perturbations from the actual conductivity model is investigated. Two mathematical expressions are derived relating the changes in the potentials and magnetic fields to conductivity perturbations. These equations show that measurements change due to secondary sources at the perturbation points. A finite element method (FEM) based formulation is developed for computing the sensitivity of measurements to tissue conductivities efficiently. The sensitivity matrices are calculated for both a concentric spheres model of the head and a realistic head model. The rows of the sensitivity matrix show that the sensitivity of a voltage measurement is greater to conductivity perturbations on the brain tissue in the vicinity of the dipole, the skull and the scalp beneath the electrodes. The sensitivity values for perturbations in the skull and brain conductivity are comparable and they are, in general, greater than the sensitivity for the scalp conductivity. The effects of the perturbations on the skull are more pronounced for shallow dipoles, whereas, for deep dipoles, the measurements are more sensitive to the conductivity of the brain tissue near the dipole. The magnetic measurements are found to be more sensitive to perturbations near the dipole location. The sensitivity to perturbations in the brain tissue is much greater when the primary source is tangential and it decreases as the dipole depth increases. The resultant linear system of equations can be used to update the initially assumed conductivity distribution for the head. They may be further exploited to image the conductivity distribution of the head from EEG and/or MEG measurements. This may be a fast and promising new imaging modality.
Subject Keywords
Radiological and Ultrasound Technology
,
Radiology Nuclear Medicine and imaging
URI
https://hdl.handle.net/11511/49120
Journal
PHYSICS IN MEDICINE AND BIOLOGY
DOI
https://doi.org/10.1088/0031-9155/49/5/004
Collections
Department of Electrical and Electronics Engineering, Article
Suggestions
OpenMETU
Core
Forward problem solution of electromagnetic source imaging using a new BEM formulation with high-order elements
Gençer, Nevzat Güneri (IOP Publishing, 1999-09-01)
Representations of the active cell populations on the cortical surface via electric and magnetic measurements are known as electromagnetic source images (EMSIs) of the human brain. Numerical solution of the potential and magnetic fields for a given electrical source distribution in the human brain is an essential part of electromagnetic source imaging. In this study, the performance of the boundary element method (BEM) is explored with different surface element types. A new BEM formulation is derived that m...
Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction
Birgul, O; Eyüboğlu, Behçet Murat; Ider, YZ (IOP Publishing, 2003-11-07)
Magnetic resonance electrical impedance tomography (MR-EIT) is an emerging imaging technique that reconstructs conductivity images using magnetic flux density measurements acquired employing MRI together with conventional EIT measurements. In this study, experimental MR-EIT images from phantoms with conducting and insulator objects are presented. The technique is implemented using the 0.15 T Middle East Technical University MRI system. The dc current method used in magnetic resonance current density imaging...
Use of a priori information in estimating tissue resistivities - a simulation study
Baysal, U; Eyüboğlu, Behçet Murat (IOP Publishing, 1998-12-01)
Accurate estimation of tissue resistivities in vivo is needed to construct reliable human body volume conductor models in solving forward and inverse bioelectric field problems. The necessary data for the estimation can be obtained by using ht four-electrode impedance measurement technique, usually employed in electrical impedance tomography. In this study, a priori geometrical information with statistical properties of regional resistivities and linearization error as well as instrumentation noise has been...
Distinguishability for magnetic resonance-electrical impedance tomography (MR-EIT)
Altunel, Haluk; Eyüboğlu, Behçet Murat; Koksal, Adnan (IOP Publishing, 2007-01-21)
A distinguishability measure is defined for magnetic resonance-electrical impedance tomography (MR-EIT) based on magnetic flux density measurements. This general definition is valid for 2D and 3D structures of any shape. As a specific case, a 2D cylindrical body with concentric inhomogeneity is considered and a bound of the distinguishability is analytically formulated. Distinguishabilities obtained with potential and magnetic flux density measurements are compared.
Lorentz force electrical impedance tomography using magnetic field measurements
ZENGİN, Reyhan; Gençer, Nevzat Güneri (IOP Publishing, 2016-08-21)
In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
N. G. Gençer, “Sensitivity of EEG and MEG measurements to tissue conductivity,”
PHYSICS IN MEDICINE AND BIOLOGY
, pp. 701–717, 2004, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/49120.