Use of fiber-reinforced polymers in slab-column connection upgrades

2005-01-01
The results of an experimental program on punching shear-strengthening of reinforced concrete slab-column connections using carbon fiber-reinforced polymers (CFRPs) are presented ill this paper. Externally installed CFRP stirrups serving as shear reinforcement were used as a strengthening technique. The effectiveness of different patterns, detailing, and various amounts of CFRP for strengthening were studied. It was found that the proposed method resulted in punching shear capacity increases up to 60% relative to the specimen without any strengthening. In addition, displacement ductility and postpunching resistance of the strengthened specimens increased, resulting in a more ductile failure mode than that of the control specimen. A design method based oil ACI 318-02 expressions is also presented for this innovative use of CFRP for strengthening slab-column connections.
ACI STRUCTURAL JOURNAL

Suggestions

Joint shear strength prediction for reinforced concrete beam-to-column connections
Unal, Mehmet; Burak Bakır, Burcu (2012-02-10)
In this analytical study numerous prior experimental studies on reinforced concrete beam-to-column connections subjected to cyclic loading are investigated and a database of geometric properties, material strengths, configuration details and test results of subassemblies is established. Considering previous experimental research and employing statistical correlation method, parameters affecting joint shear capacity are determined. Afterwards, an equation to predict the joint shear strength is formed based o...
Performance of a moment resisting beam-column connection for precast concrete construction
Baran, Eray; BARAN, MEHMET; Kurtoglu, Metin; Torra-Bilal, Ines (2021-11-01)
Seismic performance of a specific type of moment resisting precast concrete beam-column connection was investigated through reversed cyclic load tests. Structural steel components were incorporated with precast concrete beam and column elements in the experiments to provide a ductile moment resisting connection. Additionally, nonlinear finite element analysis (FEA) of typical monolithic and precast connections was performed to investigate the performance and failure modes of these connections. Concrete Dama...
Effect of column rectangularity on CFRP-strengthened RC flat plates
ERDOĞAN, HAKAN; Binici, Barış; Ozcebe, Guney (2011-07-01)
This study presents experimental and analytical research that focused on the behaviour of carbon-fibre-reinforced polymer (CFRP)-strengthened flat-slab specimens for punching shear enhancement. Seven 0.75-scale flat-slab specimens representing interior slab-column connections with different column aspect ratios varying from 1 to 3 were tested. The results revealed that increasing column rectangularity had a detrimental effect on column punching strength of all specimens. A strength increase of at least 30% ...
Estimation of lining thickness around circular shafts
Ozturk, H; Unal, E (2001-06-22)
In this paper, the broken zone developing, around a circular mine shafts and lining pressure is estimated by integrating the results of numerical analysis and the "rock-load height" equation derived from empirical analysis. During numerical modelling studies, the computer program FLAC(2D) was utilized. In order to estimate equivalent Mohr failure Envelope from the generalised Hoek Brown failure criterion, a new FISH function was written within FLAC(2D). Parametric studies were carried out by considering mRM...
Application of computer-aided injection moulding simulation for thermoplastic materials
Onalir, B; Kaftanoglu, B; Balkan, Raif Tuna (1998-01-01)
This paper presents the computer-aided simulation of an injection moulding process for thermoplastic materials. The reasons for using computer simulation for the injection moulding process are discussed together with description of the mould-filling and cooling phenomena. The paper also traces the difficulties in transferring the geometry of the part database from a computer-aided design environment to a computer-aided analysis environment by proposing several solutions for plastic products. Details of simu...
Citation Formats
B. Binici, “Use of fiber-reinforced polymers in slab-column connection upgrades,” ACI STRUCTURAL JOURNAL, pp. 93–102, 2005, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/53895.