Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Compressive Sensing Imaging with a Graphene Modulator at THz Frequency in Transmission Mode
Date
2016-09-30
Author
Özkan, Vedat Ali
Takan, Taylan
Kakenov, N.
KOCABAŞ, COŞKUN
Altan, Hakan
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
174
views
0
downloads
Cite This
In this study we demonstrate compressive sensing imaging with a unique graphene based optoelectronic device which allows us to modulate the THz field through an array of columns or rows distributed throughout its face.
URI
https://hdl.handle.net/11511/55981
Collections
Department of Physics, Conference / Seminar
Suggestions
OpenMETU
Core
Room temperature scanning micro-Hall probe microscope imaging of ferromagnetic microstructures in the presence of 2.5 Tesla pulsed magnetic fields generated by an integrated mini coil
Sandhu, A; Masuda, H; Oral, Ahmet (2002-12-01)
A unique magnetic imaging system comprising of a room temperature scanning Hall probe microscope with an integrated mini-coil capable of generating pulsed magnetic fields up to 2.5 Tesla (width of 3 ms) was developed for the direct and non-invasive magnetic imaging of ferromagnetic micro-domains in the presence of extremely large external pulsed magnetic fields without adverse vibrational disturbance of the sample during measurements. The system was successfully used for magnetic imaging of the erasure proc...
Highly Sensitive and Tunable Fano-like Rod-Type Silicon Photonic Crystal Refractive Index Sensor
Kılıç, Selahattin Cem; Kocaman, Serdar (2021-01-01)
IEEEA highly sensitive and tunable 2D rod-type silicon photonic crystal cavity based biosensor configuration has been designed and numerically analyzed. The structure is optimized so that the light-matter interaction is maximized in the cavity region. Out-of-plane light confinement is achieved by sandwiching the rods between metal plates, and tuning is achieved by introducing an air-gap between on top of the rods and the metal plate. A single rod is positioned in the middle of the waveguide so that the cavi...
Compressive sensing imaging at Sub-THz frequency in transmission mode
Özkan, Vedat Ali; Menteşe, Yıldız; Takan, Taylan; Şahin, Asaf Behzat; Altan, Hakan (Springer, Dordrecht, 2017-01-01)
Due to lack of widespread array imaging techniques in the THz range, point detector applications coupled with spatial modulation schemes are being investigated using compressive sensing (CS) techniques. CS algorithms coupled with innovative spatial modulation schemes which allow the control of pixels on the image plane from which the light is focused onto single pixel THz detector has been shown to rapidly generate images of objects. Using a CS algorithm, the image of an object can be reconstructed rapidly....
Equipotential projection based magnetic resonance electrical impedance tomography (mr-eit) for high resolution conductivity imaging
Özdemir, Mahir Sinan; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2003)
In this study, a direct reconstruction algorithm for Magnetic Resonance Electrical Impedance Tomography (MR-EIT) is proposed and experimentally implemented for high resolution true conductivity imaging. In MR-EIT, elec trical impedance tomography (EIT) and magnetic resonance imaging (MRI) are combined together. Current density measurements are obtained making use of Magnetic Resonance Current Density Imaging (MR-CDI) techniques and peripheral potential measurements are determined using conventional EIT tech...
Electrical impedance tomography using the magnetic field generated by injected currents
Birgul, O; Ider, YZ (1996-11-03)
In 2D EIT imaging, the internal distribution of the injected currents generate a magnetic field in the imaging region which can be measured by magnetic resonance imaging techniques. This magnetic field is perpendicular to the imaging region on the imaging region and it can be used in reconstructing the conductivity distribution inside the imaging region. For this purpose, internal current distribution is found using the finite element method. The magnetic fields due to this current is found using Biot-Savar...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
V. A. Özkan, T. Takan, N. Kakenov, C. KOCABAŞ, and H. Altan, “Compressive Sensing Imaging with a Graphene Modulator at THz Frequency in Transmission Mode,” 2016, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/55981.