Determination of lithium in human blood serum by discrete nebulization flame atomic emission spectrometry

Download
2001
Aksoy, Eda Ayşe

Suggestions

Determination of selenium in human blood by graphite furnace and hydride generation atomic absorption spectrometry
Özbaba, Füsun; Gökmen, İnci; Department of Chemistry (1988)
Determination of zinc in aerosol samples by discrete nebulization flame atomic absorption spectrometry
Sarica, DY; Akim, D; Ozden, T (2002-01-01)
A well-known analytical method, "discrete nebulization", which is suitable for samples having a limited amount like body fluids, high solid content or salt solutions, and less volatile metals, has been further developed for zinc determination in aerosol samples.
Determination of Phthalates in Milk by Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
Tuncel, Süleyman Gürdal (2016-01-01)
Ultrasound-assisted dispersive liquid-liquid microextraction was coupled with gas chromatography-mass spectrometry for the determination of phthalate esters in milk. Dimethyl phthalate, diethyl phthalate, dibutyl phthalate, benzyl butyl phthalate, bis(2-ethylhexyl) phthalate, and dioctyl phthalate were analyzed in five brands of pasteurized Turkish milk. The efficiencies of the extraction procedure for the analytes were between 66 and 100%. The linear dynamic ranges of the calibration curves were from 0.025...
Determination of selenium in biolgical fluids and tissues in healthy and diseased children by hydride generation atomic absorption spectrometry
Diab, Nizam Ahmad; Gökmen, İnci; Ataman, O. Yavuz; Department of Chemistry (1990)
Determination of cadmium in high salt content matrices by flow injection cold vapor atomic absorption spectrometry
Alp, Orkun; Demiroz, Hakan; Ataman, Osman Yavuz; ERTAŞ, Nusret (2012-01-01)
Flow injection cold vapor atomic absorption spectrometry (FI-CVAAS) was used for determination of cadmium in high salt matrices such as dialysis concentrates and textile leach solutions. The parameters such as acidity, concentration of reducing agent, reaction coil length, and carrier gas flow rate were investigated to obtain the best sensitivity. No significant background signal was observed even at high salt concentrations. Under the optimized conditions the limit of detection value (3s(b) m(-1), where s(...
Citation Formats
E. A. Aksoy, “Determination of lithium in human blood serum by discrete nebulization flame atomic emission spectrometry,” Middle East Technical University, 2001.