Implementation of enchanced network file system

Download
1996
Özel , Melda

Suggestions

Implementation of a multiband excitation speech coder
İnevi, Mete; Demirekler, Mübeccel; Department of Electrical and Electronics Engineering (1999)
Implementation of a communication system for distribution automation based on telephone network
Altınoluk, Hasan; Güven, Nezih; Büyüksemerci, Ayhan; Department of Electrical and Electronics Engineering (1996)
Implementation of software GPS receiver
Günaydın, Ezgi; Tuncer, Temel Engin; Department of Electrical and Electronics Engineering (2005)
A software GPS receiver is a functional GPS receiver in software. It has several advantages compared to its hardware counterparts. For instance, improvements in receiver architecture as well as GPS system structure can be easily adapted to it. Furthermore, interaction between nearby sensors can be coordinated easily. In this thesis, a SGR (software GPS receiver) is presented from a practical point of view. Major components of the SGR are implemented in Matlab environment. Furthermore, some alternative algor...
Implementation of a data acquisition system for contactless conductivity imaging
ULKER, B; Gençer, Nevzat Güneri (2001-10-28)
A data acquisition system is realized to image electrical conductivity of biological tissues via contactless measurements. This system uses magnetic excitation to induce currents inside the body and measures the magnetic fields of the induced currents. A magnetically coupled differential coil system is scanned on the conductive object by a computer controlled scanning system. A data acquisition system is constructed using a PC controlled lock-in amplifier. 1.64V secondary voltage difference can be measured ...
Implementation of a data acquisition system for contactless conductivity imaging
Ulker, B; Gençer, Nevzat Güneri (2002-09-01)
A data acquisition system is realized for conductivity imaging via contactless measurements. It is observed that field profiles are good representatives of the conductive objects scanned by the measurement system. Three different data sets are taken with different scanning resolutions. Note that although the scanning resolution is decreased 25 times, it is still possible to observe the conductive object. The data acquisition time is due to the data acquisition time limit of the lock-in amplifier. As might b...