Forced Vibration Testing of Reinforced Concrete Buildings
Çelik, Ozan Cem; Sucuoğlu, Haluk; Akyüz, Uğurhan (2003-05-26)
Forced Vibration Testing and Finite Element Modeling of a Nine-Story Reinforced Concrete Flat Plate-Wall Building
Çelik, Ozan Cem; Sucuoğlu, Haluk; Akyüz, Uğurhan (SAGE Publications, 2015-05-01)
Tunnel form buildings, owing to their higher construction speed and quality, lower cost, and superior earthquake resistance over that of conventional reinforced concrete buildings, have been widely used for mass housing, urban renewal, and post-earthquake reconstruction projects all over the world as well as in Turkey. However, there have been few dynamic tests performed on existing buildings with this structural system. This study investigates the dynamic structural properties of a typical nine-story reinf...
Forced Vibration Testing and Seismic Fragility Assessment of Instrumented Structures (FORAGAINST)
Çelik, Ozan Cem(2016-2-07)
The objectives of this proposed research are to perform forced vibration tests on the following reinforced concrete structures, which are permanently instrumented for recording their dynamic responses in the case of future earthquakes in Turkey: a four-story dormitory building in Bolu, a four-story office building in Istanbul, a five-story hospital building in Antakya, a three-story school building in Antakya, and a four-story university building in Izmir, and to derive seismic fragilities for these structu...
Creep deformation in reinforced concrete beams.
Atımtay, Ergin; Department of Civil Engineering (1967)
Passive damping and seismic isolation steel devices with displacement-dependent hardening
Dicleli, Murat (null; 2018-02-02)
In this paper, a summary of analytical and experimental studies into the behaviour of a new hysteretic damper and a seismic isolator designed for seismic protection of structures is presented. The Multi-directional Torsional Hysteretic Damper (MRSD) and its isolator version MARTI (Multi-Directional Adaptive Torsional Isolator) are patented inventions in which a symmetrical arrangement of identical cylindrical steel cores is so configured as to yield in torsion while the structure experiences planar movement...