A labview interface to integrate magnetic resonance imaging (MRI) simulator with system control and its application to regional magnetic resonance electrical impedance tomography (MREIT) reconstruction

Download
2010
Topal, Tankut
Magnetic resonance imaging (MRI) is a high resolution medical imaging technique based on distinguishing tissues according to their nuclear magnetic properties. Magnetic resonance electrical impedance tomography (MREIT) is a conductivity imaging technique which reconstructs images of electrical properties, based on their effect on induced magnetic flux density due to externally applied current flow. Both of these techniques are of interest for novel research and development. Simulators help researchers observe the accuracy and the results of the study. In this study a user friendly complete MRI/MREIT simulator is designed. This simulator is the combination of improved version of MRI simulator (implemented by V. E. Arpinar, H. Yigitler), a forward solver, to observe the current injection effect, the improved version of user interface that is designed on LabVIEW graphical programming environment (designed by M. Ozsut), and equi-potential projection (EPP) reconstruction algorithm (proposed by M. S. Ozdemir, M. Eyuboglu, O. Ozbek). All of these individual parts are improved and gathered in LabVIEW environment in order to work in synchrony. In addition to that, regional image reconstruction technique (proposed by H. Altunel, M. Eyuboglu) is also included in the simulator. The simulator is run for various inputs and system specifications. It is observed that the simulation results are consistent with the expected results for MRI, MREIT and conventional/regional MREIT reconstruction. Four different models are designed and results are obtained using these models. The accuracy of the results usually differs with the input parameters and model geometry. Validating numerically the accuracy of the forward solution part using Biot-Savart and Ampere's laws, the consistency of the forward problem solution part is obtained at a percentage of 95%. In the MREIT part, magnetic flux density distribution taken from forward solver part is added to the main magnetic flux density used in the MRI part. Consistency of the magnetic flux density distribution given to the simulator as input and the output taken from the MREIT part of the simulator is found as 99%. In addition to conventional EPP algorithm, regional MREIT reconstruction algorithm is applied for various noise levels. It is observed that, as the noise level increases, regional MREIT reconstruction algorithm gives relatively much better results compared to conventional MREIT reconstruction algorithm. Errors obtained by applying conventional reconstruction and regional reconstruction are compared for each inhomogeneity individually. Therefore, accuracies of the different current patterns depending on the inhomogeneities are observed as well.

Suggestions

Multi-frequency electrical conductivity imaging via contactless measurements
Özkan, Koray Özdal; Gençer, Nevzat Güneri; Department of Electrical and Electronics Engineering (2006)
A multi-frequency data acquisition system is realized for subsurface conductivity imaging of biological tissues. The measurement procedures of the system at different frequencies are same. The only difference between the single frequency experiments and the multi-frequency experiments is the hardware, i.e. the sensor and the power amplifier used in the single frequency experiments was different than that were used in the multi-frequency experiments. To avoid confusion the measurement system with which the s...
Electrical and structural characterization of bismuth thin films
Durkaya, Göksel; Parlak, Mehmet; Department of Physics (2005)
Electrical and structural properties of Bismuth thin films were studied simultaneously. Electrical properties of the Bismuth thin films have been characterized by measuring temperature dependent conductivity and Hall effect. Structural analysis were carried out by X-ray diffraction technique and using a room temperature Atomic Force Microscope (RT-AFM).
Preparation and characterization of magnetite nanoparticles by thermal decomposition method for their potential use in tumor imaging
Tatlıcı, Zehra; Volkan, Mürvet; Department of Chemistry (2010)
In biomedical applications, magnetic nanoparticles have been used as they offer attractive possibilities. First, they have controllable sizes ranging from a few nanometers up to tens of nanometers and second, the nanoparticles are magnetic and magnetic fields can penetrate into human tissue which means that they can be manipulated by an external magnetic field gradient. In this study, Fe₃O₄ nanoparticles are synthesized by thermal decomposition method for their potential use in cancer diagnosis. Techniques ...
Visualisation of cakes differing in oil content with magnetic resonance imaging
Kırtıl, Emrah; Aydogdu, AYÇA; Bulut, Elif Yildiz; Tatar, Betul Cilek; Öztop, Halil Mecit (Informa UK Limited, 2017-01-01)
Magnetic resonance imaging (MRI) is a non-invasive imaging technique that can visualise samples' interior by using the signal coming from mobile protons. The aim of this study was to examine the effects of oil content and peanut/raisin addition on cake quality and to illustrate the power of MRI in analysis of moisture and oil distribution. For this purpose, MR images were acquired with a spin echo sequence and relaxation times T-1 and T-2, and moisture content and firmness of cakes were measured. High oil c...
An Improved Receiver for Harmonic Motion Microwave Doppler Imaging
Soydan, Damla Alptekin; Irgin, Umit; Top, Can Baris; Gençer, Nevzat Güneri (2020-03-01)
© 2020 EurAAP.Harmonic motion microwave Doppler imaging is a novel imaging modality that combines focused ultrasound and radar techniques to obtain data based on mechanical and electrical properties of the tissue. In previous experimental studies, the Doppler component of the scattered signal is sensed and used to create 2D images of a tumor inside a homogeneous fat phantom. Due to the drawbacks of the receiver configuration, scanning time was high, the signal-to-noise ratio was low, and the multi-frequency...
Citation Formats
T. Topal, “A labview interface to integrate magnetic resonance imaging (MRI) simulator with system control and its application to regional magnetic resonance electrical impedance tomography (MREIT) reconstruction,” M.S. - Master of Science, Middle East Technical University, 2010.