Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Design and verification of diamond based capacitive micromachined ultrasonic transducer
Download
index.pdf
Date
2011
Author
Çetin, Ahmet Murat
Metadata
Show full item record
Item Usage Stats
196
views
105
downloads
Cite This
Potential applications such as high intensity focused ultrasound in medical therapeutics require larger output pressures. To offer unprecedented acoustic output pressure in transmit without the limitations, Capacitive Micromachined Ultrasonic Transducer operation modes of collapse and collapse-snapback are introduced in literature. Both operation modes require the membrane to contact the substrate surface, which poses a problem on the durability of the membrane in terms of structural integrity and tribological property. Based on the additional requirements of these modes, diamond is proposed as the ultimate solution to be used as the membrane material. Mechanical, thermal, and electrical properties of diamond are all in favor of its use in the microfabrication of CMUTs. This thesis introduces the design and test results of the first diamond-based CMUTs as an alternative to silicon and silicon nitride based CMUTs. Simulations are performed using Finite Element Methods (FEM) using a commercially available software package, ANSYS. The diamond-based CMUT is operated successfully both in air and immersion for the first time. Fully customizable in-house software is developed to command and control the test setup equipments for current dissertation and future work. Fresnel and Fraunhofer regions of the CMUT are characterized in sunflower oil using a combination of advanced hardware and software. The experimental results of radiation and diffraction for the diamond-based circular CMUT are verified by the theoretical calculations for a circular piston transducer. The results obtained from the first generation diamond-based CMUTs presented the diamond as a promising material for membranes in CMUTs.
Subject Keywords
Ultrasonic testing.
,
Finite element method
URI
http://etd.lib.metu.edu.tr/upload/12612960/index.pdf
https://hdl.handle.net/11511/20490
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Formulation and implementation of a fractional order viscoelastic material model into finite element software and material model parameter identification using in-vivo indenter experiments for soft biological tissues
Demirci, Nagehan; Tönük, Ergin; Department of Mechanical Engineering (2012)
Soft biological tissue material models in the literature are frequently limited to integer order constitutive relations where the order of differentiation of stress and/or strain is integer-valued. However, it has been demonstrated that fractional calculus theory applied in soft tissue material model formulation yields more accurate and reliable soft tissue material models. In this study, firstly a fractional order (where the order of differentation of stress in the constitutive relation is non-integer-valu...
Integrated circuit design for flip-chip bonded capacitive micromachined ultrasonic transducers
Maadi, Muhammad; Bayram, Barış; Department of Electrical and Electronics Engineering (2013)
In previous decades, the applications of ultrasound technologies in medical imaging and therapeutic systems have significantly increased. In conventional ultrasound systems, the transducer array is separated from the electronic instrumentation with multicore physical cabling. However, connection cables make the system too bulky and degrade the receive sensitivity in ultrasound 3D imaging applications because of the capacitance of long cables. The interface electronics for phased array ultrasound systems (im...
Design and Optimization of Nanoantennas for Nano-Optical Applications
Işıklar, Göktuğ; Ergül, Özgür Salih; Department of Electrical and Electronics Engineering (2020-9)
In this study, design and simulation of plasmonic nanoantenna structures to obtain high power enhancement capabilities at optical frequencies, as well as utilization of nanoantennas for imaging and sensing applications are presented. Plasmonic characteristics of nanoantennas, which depend on many parameters, such as material, frequency, geometry, and size, are investigated in detail via computational analyses of various nanoantenna structures. Numerical solutions of electromagnetic problems are performe...
Hygrothermal fracture analysis of fibrous composites with variable fiber spacing using JK-integral
Saeidi, Farid; Dağ, Serkan; Department of Mechanical Engineering (2013)
In this study, a Jk-integral based computational method will be developed to conduct fracture analysis of fibrous composite laminates that possess variable fiber spacing. This study will be carried out for the fibrous composites exposed to not only thermal but also hygroscopic boundary condition, which results hygrothermal load. Formulation of the Jk-integral will be carried out by using the constitutive relations of plane orthotropic hygrothermoelasticity. One of the most important challenges of this study...
ESTIMATION OF TISSUE RESISTIVITIES FROM MULTIPLE-ELECTRODE IMPEDANCE MEASUREMENTS
Eyüboğlu, Behçet Murat; WOLF, PD (IOP Publishing, 1994-01-01)
In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in this study. A statistically constrained minimum-mean-square error estimator (MIMSEE) that minimizes the effects of linearization errors and instrumentation noise is developed and compared to the c...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. M. Çetin, “Design and verification of diamond based capacitive micromachined ultrasonic transducer,” M.S. - Master of Science, Middle East Technical University, 2011.