Elimination of transformer core saturation in cascaded multilevel converter based T-STATCOM systems

Download
2014
Gerçek, Cem Özgür
This research work is devoted to the description of coupling transformer core saturation phenomenon and its elimination by modulated firing algorithms in Cascaded Multilevel Converter (CMC) based T-STATCOM systems. Transmission- type Static Synchronous Compensator (T-STATCOM) is connected to the transmission voltage level (≥110kV) via a coupling transformer. The coupling transformer may be an existing Medium Voltage (MV) to High Voltage (HV) or Extra High Voltage (EHV), or a specially designed transformer. This thesis work deals with coupling transformer core saturation problem in Cascaded Multilevel Converter (CMC) based T-STATCOM systems. The effects of nonlinear characteristics of the coupling transformer and CMCs on the core saturation phenomenon are investigated, and the associated mechanisms are described. İmbalance in positive and negative cycles of the converter output voltage waveform, 2nd harmonic voltage at the ac primary side, and low operation flux density of the vi transformer may lead to asymmetric saturation of the coupling transformer core. Transformer core saturation results in significant increase in not only in dc current but also in the 2nd harmonic current and hence voltage component at the ac side of the converter. Furthermore, the 2nd harmonic voltage component will be reflected to the dc side of the converter in the form of ac voltage component at supply frequency. Dc current components in the coupling transformer secondary lines are eliminated by modulating one or more than one voltage steps of staircase CMC voltage waveforms via the electronic gating circuitry. The proposed dc current elimination method is implemented on a 154-kV, ±50-MVAr CMC based T-STATCOM system, which is operating either in inter-area oscillation damping or terminal voltage regulation modes at any time in a 400/154-kV transformer substation since March 2010. The effectiveness of recommended dc current elimination method is verified in the field.

Suggestions

Elimination of Coupling Transformer Core Saturation in Cascaded Multilevel Converter-Based T-STATCOM Systems
Gercek, Cem Ozgur; Ermiş, Muammer (2014-12-01)
This paper deals with coupling transformer core saturation problem in cascaded multilevel converter (CMC) based transmission-type static synchronous compensator (T-STATCOM) systems. The effects of nonlinear characteristics of the coupling transformer and CMCs on the core saturation phenomenon are investigated, and the associated mechanisms are described. In order to prevent the transformer core from being saturated, dc current components in the coupling transformer secondary lines are eliminated by modulati...
Cascaded multilevel converter based transmission STATCOM : system design methodology and development of 12kV ±12MVAr power stage
Gültekin, Burhan; Ermiş, Muammer; Department of Electrical and Electronics Engineering (2012)
This research and development work deals with the design methodology for Cascaded Multilevel Converter (CMC) based Transmission STATCOM (TSTATCOM) and development of a ±12MVAR, 12kV line-to-line wye-connected, 11-level CMC. This CMC module constitutes the basic building block of TSTATCOM systems. Sizing of the CMC module, number of H-Bridges in each phase of the CMC, AC voltage rating of the CMC, the number of paralleled CMC modules in the T-STATCOM system, optimum value of series filter reactors and determ...
Modeling and design of iron-core shunt reactors with discretely distributed air-gaps
Dönük, Atilla; Ermiş, Muammer; Bilgin, Hazım Faruk; Department of Electrical and Electronics Engineering (2012)
In this research work detailed parallel and series equivalent circuits of a gapped iron-core shunt reactor with discretely distributed gaps are derived. The validity of the recommended equivalent circuits is verified by Finite Element Analysis and laboratory tests. Effects of fringing flux and discretely distributed gaps on inductance parameters and reactor losses are also investigated. Moving Strip Method for discretely distributed gapped shunt reactors is recommended. Two design procedures for shunt react...
Measurement of the production cross section for pairs of isolated photons in pp collisions at root s=7 TeV
Chatrchyan, S.; et. al. (Springer Science and Business Media LLC, 2012-01-01)
The integrated and differential cross sections for the production of pairs of isolated photons is measured in proton-proton collisions at a centre-of-mass energy of 7TeV with the CMS detector at the LHC. A data sample corresponding to an integrated luminosity of 36 pb(-1) is analysed. A next-to-leading-order perturbative QCD calculation is compared to the measurements. A discrepancy is observed for regions of the phase space where the two photons have an azimuthal angle difference Delta phi less than or sim...
Online characterization of interharmonics and harmonics of AC electric arc furnaces by multiple synchronous reference frame analysis
Uz Loğoğlu, Eda; Salor, Özgül; Ermiş, Muammer (2015-10-18)
In this paper, a multiple synchronous reference frame (MSRF) analysis framework is developed to determine the positive- and negative -sequence components of all interharmonic and harmonic currents produced by alternating current electric arc furnace (AC EAF) installations, which can be considered as balanced but asymmetrical three-phase, three -wire loads on the power system. The aim of developing the MSRF analysis framework is two -fold; deep understanding of the EAF characteristics, and fast and accurate ...
Citation Formats
C. Ö. Gerçek, “Elimination of transformer core saturation in cascaded multilevel converter based T-STATCOM systems,” Ph.D. - Doctoral Program, Middle East Technical University, 2014.