Experimental analysis of an auxiliary air conditioning system used in an armored vehicle

Download
2015
Korkmaz, Alper
In this thesis study, the theoretical design phases and experiments are performed about the air conditioning unit for a specific military vehicle, which is designed to be driven by an Auxiliary Power Unit (APU) system. The purpose is to determine the vapor compression refrigeration cycle characteristics under different load conditions on both the evaporator and the condenser as well as observe the particular mass flow rates considering the vapor and liquid phases of the refrigerant. Additionally, all experiment results are compared in terms of pressures, temperatures, relevant mass flow rates as well as performance characteristics such as COP, volumetric, isentropic and exergetic efficiencies, condenser heat rejection rate, evaporator cooling capacity and compressor work. The APU systems are commonly used in military vehicles to power the any required units/systems, desired to run externally. Details of the APU system are explained in the following chapters. In present study, APU is purposed to run the compressor of the A/C system. Accordingly, A/C system has also other main components such as; evaporator unit with expansion valve and receiver-filter-dryer, and condenser module. Considering these, the thermodynamic cycle analysis of the whole A/C system is conducted as well as componentwise analysis. In the tests, the temperatures and the pressures at the inlet/outlet of the components are recorded. In addition, mass flow rates in the both high-pressure (liquid) and low-pressure (vapor) sides are observed. All these data are internally compared according to the experiments results to observe the efficiency of refrigeration vapor compression cycle as well as for better understanding the dynamics of the A/C system. In conclusion, test setup is prepared to perform six different load configurations on the evaporator and condenser, and relevant results are presented accordingly.

Suggestions

Numerical investigation on the effect of transversal fluid field deformation on heat transfer in a rod bundle with mixing vanes
Tas-Koehler, Sibel; Lecrivain, Gregory; Krepper, Eckhard; Unger, Sebastian; Hampel, Uwe (Elsevier BV, 2020-05-01)
Spacer grids of fuel rod assemblies are equipped with vanes, which promote flow mixing and turbulence within and across the sub-channels, thereby enhancing the heat transfer. First, a literature study about the various effect of the spacer grid has on the sub-channel thermo-hydrodynamics is provided. It follows, that the multiple effects on the vane angle are insufficiently understood. The effect of the vane angle on design parameters, namely the evolution of the Nusselt number, the pressure drop, the cross...
Optimisation and design of PV modules for the application on bus roof-top and system integration for solar cooling
DEMİRCİOĞLU, Olgu; ES, FIRAT; Çiftpınar, Emine Hande; ZEYBEK, Akin; TUNCER, Cahit; Turan, Raşit (2015-09-18)
In this study, an external electrical cooling unit powered by PV modules was installed on the roof‐top of a bus to keep cooled interior atmosphere at a certain temperature level during the journey breaks. All solar cells used in this project were fabricated by Center for Solar Energy Research and Applications (GUNAM) and; then, integrated onto a bus roof together with MAN Turkey A.Ş. For integration of PV modules onto roof of bus, a reliable and commercially applicable method has been developed. Following i...
Experimental Investigation of Effusion and Film Cooling for Gas Turbine Combustor
İnanlı, Sinan; Yasa, Tolga; Ulaş, Abdullah (2016-07-12)
Experimental study was conducted to understand the heat transfer characteristics of film or effusion cooled test plates that represent the gas turbine combustor liner. Two effusion cooling test plates having different hole angles (30 and 75° with horizontal) were used. Film cooling tests were conducted by six different slot geometries. Test geometries were the scaled-up model of real combustor liner. Three different blowing ratios were applied for each test plate geometry. Surface cooling effectiveness was ...
Experimental Investigation of the Anti Vortex Devices of Beyhan 1 Dam and Hydroelectric Power Plant Water Intake Structure
Göğüş, Mustafa; Altan Sakarya, Ayşe Burcu; Köken, Mete (2016-06-17)
Hydraulic model tests of the intake structure of Beyhan 1 Dam having four units were carried out at Hydromechanics Laboratory of Middle East Technical University, Ankara In order to investigate the flow pattern, and formation, development and dissipation of vortices at the intake structure under different operation conditions of the units, and to determine the types of anti-vortex devices to avoid the air-entraining vortices, a model of 1/29.43 length scale was constructed. The model area covers an about 20...
Compatibility Issues Between the Filter and PWM Unit in Three-Phase AC Motor Drives Utilizing the Pure Sine Filter Configuration
Cetin, N. Onur; Hava, Ahmet Masum (2011-11-01)
Inserted between the inverter and the ac motor for the purpose of providing clean sinusoidal voltage at the motor terminals, the pure sine filter (PSF) involves common-mode and differential-mode suppression components. When using PSF in a motor drive and employing advanced pulsewidth modulation (PWM) techniques with discontinuous modulation waveforms, a large common-mode current may circulate through the inverter and the filter resulting in overcurrent stress in the inverter and significant acoustic noise i...
Citation Formats
A. Korkmaz, “Experimental analysis of an auxiliary air conditioning system used in an armored vehicle,” M.S. - Master of Science, Middle East Technical University, 2015.