Source Apportionment of Personal Exposure to Fine Particulate Matter and Volatile Organic Compounds using Positive Matrix Factorization

2013-01-01
PEKEY, HAKAN
PEKEY, BEYHAN
ARSLANBAŞ, DEMET
BOZKURT, ZEHRA
DOĞAN, GÜRAY
Tuncel, Süleyman Gürdal
The objective of this study was to identify potential sources of personal exposure to fine particulate matter (PM2.5), volatile organic compounds (VOCs), NO2, SO2, and O-3 in an urban and industrial area of Turkey between May 2006 and January 2007. Personal exposures were determined once per person in 28 adults over a 24-h period. Energy dispersive Xray fluorescence and a wavelength dispersive X-ray fluorescence spectrometry were used to measure 15 elements in PM2.5, including Al, As, Ca, Cr, Cu, Fe, K, Mn, Ni, Pb, S, Si, Ti, V, and Zn. The VOCs benzene, toluene, m/p-xylene, o-xylene, ethylbenzene, styrene, cyclohexane, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, hexane, heptane, nonane, octane, decane, undecane, and dodecane were measured by thermal desorption and gas chromatography/flame ionization. Application of positive matrix factorization to the data obtained suggests that motor vehicles, indoor sources, and industry represent the main emission sources of the investigated chemical species. Six major sources smoking (9 %), industry (15 %), gasoline exhaust (21 %), indoor sources (17 %), diesel exhaust (19 %), and crustal (19 %) were identified.
WATER AIR AND SOIL POLLUTION

Suggestions

Source Identification of Volatile Organic Compounds and Particulate Matters in an Urban and Industrial Areas of Turkey
PEKEY, BEYHAN; PEKEY, HAKAN; DOĞAN, GÜRAY; Tuncel, Süleyman Gürdal; Arslanbaşı, Demet; BOZKURT, ZEHRA (2015-06-01)
Elevated levels of volatile organic compounds (VOCs) and particulate matters have been observed in recent years in Kocaeli, Turkey, despite improvements in pollution prevention technology that have led to a reduction in gas and particulate emissions. Local authorities should devise alternative strategies to reduce the possible health effects of a variety of pollutants that affect air quality. The objective of this study was to identify potential sources of VOCs, fine particulate matter (PM2.5) and coarse pa...
Source apportionment of trace elements in Ankara
Çelik, İlke; Sanin, Faika Dilek; Department of Environmental Engineering (2014)
In this study, chemical composition of aerosol samples in Ankara is identified through receptor modeling. Within the scope of the study, 24-hr aerosol samples are collected by ‘Stack Filter Unit’ with using Nuclepore filter for 9 months at Middle East Technical University campus as a suburban sampling location. Collected filters are analyzed for fifty-seven major and minor trace elements, between z=3 Li and z = 92 (U) and black carbon. Measured concentrations of fine and coarse fractions are compared with c...
Source identification of VOCs in METU campus through factor analysis
Uzunpınar, Elif Sena; Ezgi, Sert; Aslan Kılavuz, Seda; İmamoğlu, İpek; Tuncel, Süleyman Gürdal (null; 2016-09-03)
In this study, 55 ozone precursor VOCs, which are routinely measured in PAMS (Photochemical Assessment Monitoring Station) were measured in a suburban station located at Middle East Technical University, Environmental Engineering Department in, Ankara. Daily air samples were collected in evacuated canisters between January – December, 2014. Collected samples were analyzed with GC-FID system and concentrations of 51 VOCs were determined. Mean VOC concentrations ranged 0.048±0.061 μg.m-3 (cis- 2-penten) and 1...
Source apportionment of volatile organic compounds in Ankara atmosphere
Uzunpınar, Elif Sena; İmamoğlu, İpek; Tuncel, Süleyman Gürdal; Department of Environmental Engineering (2015)
In this study, ambient concentrations of volatile organic compounds (VOCs) of Photochemical Assessment Monitoring Stations (PAMS) in Ankara atmosphere were measured to determine the current level and sources of these compounds. Sampling was performed at METU Department of Environmental Engineering from January, 2014 to December, 2014 with stainless-steel canisters. Mean VOC concentrations ranged between 0.04 μg m-3 (cis-2-pentene) and 10.30 μg m-3 (toluene) with average benzene concentration of 1.49 μg m-3....
Source identification of VOCs in METU Campus through factor analysis
Uzunpınar, Elif Sena; Kilavuz, Aslan S.; İmamoğlu, İpek (2018-02-01)
In this study, 51 ozone precursor VOCs, which are routinely measured in PAMS (Photochemical Assessment Monitoring Station) were measured in a suburban station located at Middle East Technical University, Environmental Engineering Department in, Ankara. Daily air samples were collected in evacuated canisters between January December, 2014. Collected samples were analyzed with GC-FID system and concentrations of 51 VOCs were determined. Mean VOC concentrations ranged between 0.048 +/- 0.061 mu g m(-3) (cis-2-...
Citation Formats
H. PEKEY, B. PEKEY, D. ARSLANBAŞ, Z. BOZKURT, G. DOĞAN, and S. G. Tuncel, “Source Apportionment of Personal Exposure to Fine Particulate Matter and Volatile Organic Compounds using Positive Matrix Factorization,” WATER AIR AND SOIL POLLUTION, pp. 0–0, 2013, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/29999.