Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Source identification of VOCs in METU Campus through factor analysis
Date
2018-02-01
Author
Uzunpınar, Elif Sena
Kilavuz, Aslan S.
İmamoğlu, İpek
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
165
views
0
downloads
Cite This
In this study, 51 ozone precursor VOCs, which are routinely measured in PAMS (Photochemical Assessment Monitoring Station) were measured in a suburban station located at Middle East Technical University, Environmental Engineering Department in, Ankara. Daily air samples were collected in evacuated canisters between January December, 2014. Collected samples were analyzed with GC-FID system and concentrations of 51 VOCs were determined. Mean VOC concentrations ranged between 0.048 +/- 0.061 mu g m(-3) (cis-2-penten) and 10 +/- 13 mu g m(-3) (toluene). Average benzene concentration was 1.49 +/- 1.74 mu g m(-3). Factor Analysis (FA) was applied to determine the major sources of VOCs that contribute to the measured concentrations in the university campus. FA application revealed nine factors that can be grouped under four major components, including (1) transportation: gasoline vehicle exhaust emissions, evaporative losses from gasoline vehicles, gasoline evaporation in gas stations and diesel emissions, (2) industrial emissions: industrial evaporation and industrial application, (3) solvent emissions: surface coatings and solvent use and (4) asphalt application.
Subject Keywords
Source Apportionment
,
Canister
URI
https://hdl.handle.net/11511/53438
Journal
GLOBAL NEST JOURNAL
Collections
Department of Environmental Engineering, Article
Suggestions
OpenMETU
Core
Source identification of VOCs in METU campus through factor analysis
Uzunpınar, Elif Sena; Ezgi, Sert; Aslan Kılavuz, Seda; İmamoğlu, İpek; Tuncel, Süleyman Gürdal (null; 2016-09-03)
In this study, 55 ozone precursor VOCs, which are routinely measured in PAMS (Photochemical Assessment Monitoring Station) were measured in a suburban station located at Middle East Technical University, Environmental Engineering Department in, Ankara. Daily air samples were collected in evacuated canisters between January – December, 2014. Collected samples were analyzed with GC-FID system and concentrations of 51 VOCs were determined. Mean VOC concentrations ranged 0.048±0.061 μg.m-3 (cis- 2-penten) and 1...
Source Apportionment of Personal Exposure to Fine Particulate Matter and Volatile Organic Compounds using Positive Matrix Factorization
PEKEY, HAKAN; PEKEY, BEYHAN; ARSLANBAŞ, DEMET; BOZKURT, ZEHRA; DOĞAN, GÜRAY; Tuncel, Süleyman Gürdal (2013-01-01)
The objective of this study was to identify potential sources of personal exposure to fine particulate matter (PM2.5), volatile organic compounds (VOCs), NO2, SO2, and O-3 in an urban and industrial area of Turkey between May 2006 and January 2007. Personal exposures were determined once per person in 28 adults over a 24-h period. Energy dispersive Xray fluorescence and a wavelength dispersive X-ray fluorescence spectrometry were used to measure 15 elements in PM2.5, including Al, As, Ca, Cr, Cu, Fe, K, Mn,...
Source apportionment of volatile organic compounds in Ankara atmosphere
Uzunpınar, Elif Sena; İmamoğlu, İpek; Tuncel, Süleyman Gürdal; Department of Environmental Engineering (2015)
In this study, ambient concentrations of volatile organic compounds (VOCs) of Photochemical Assessment Monitoring Stations (PAMS) in Ankara atmosphere were measured to determine the current level and sources of these compounds. Sampling was performed at METU Department of Environmental Engineering from January, 2014 to December, 2014 with stainless-steel canisters. Mean VOC concentrations ranged between 0.04 μg m-3 (cis-2-pentene) and 10.30 μg m-3 (toluene) with average benzene concentration of 1.49 μg m-3....
Sources of volatile organic compounds at urban and rural Kütahya atmosphere
Bek, Tuğçe; Tuncel, Süleyman Gürdal; Department of Environmental Engineering (2015)
This study is a part of a fairly extensive study to investigate contributions of the two thermal power plants, Tunçbilek and Seyitömer, on air quality at Kütahya atmosphere. VOCs were measured at two sampling stations, one was established in the down-town of Kütahya and the other one in the Northeast of the Kütahya. Samples were collected using canisters and they were analyzed using GC-FID system. Average concentrations of VOCs varied between 0.12 g/m3 and 23 g/m3 at urban station and 0.06 g/m3 and 33 g...
Source apportionment of trace elements in the Eastern Mediterranean atmosphere
GÜLLÜ, GÜLEN; Ölmez, İlhan; Tuncel, Süleyman Gürdal (2004-01-01)
Concentrations of elements and ions, measured in aerosol samples collected during 1993 were investigated to identify sources and source composition of aerosols in the Eastern Mediterranean atmosphere. The factor analysis have shown that Eastern Mediterranean aerosol is a four-component system, including a crustal component, long-range transported pollution component, a marine component and a local pollution component. Main anthropogenic component, which reaches to the region by long-range transport accounts...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
E. S. Uzunpınar, A. S. Kilavuz, and İ. İmamoğlu, “Source identification of VOCs in METU Campus through factor analysis,”
GLOBAL NEST JOURNAL
, pp. 109–114, 2018, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/53438.