Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
On-line fouling/cleaning detection by measuring electric resistance-equipment development and application to milk fouling detection and chemical cleaning monitoring
Date
2004-02-01
Author
Chen, Xiao Dong
Li, Dolly X.Y.
Lin, Sean X.Q.
Özkan, Necati
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
153
views
0
downloads
Cite This
n electrical resistance method, which has the potential to measure the extent of soft material fouling such as milk fouling on the surface of process equipment in situ and in real time, is described. An experimental fouling unit with the appropriate attachments has been devised and used to monitor the fouling build-up using the electrical resistance method. Reconstituted skim milks with solid contents of 10-30 wt.% were used to produce milk foulings, and these milk foulings were cleaned using a cleaning solution with 0.5 wt.% NaOH. Using the fouling unit, it was possible to measure the thermal resistance (essentially measuring heat flux) and electrical resistance simultaneously. As a result, the relationship between the electrical resistance and the thermal resistance during both fouling build-ups and cleaning processes was established. It has been shown that this technique is effective for measuring the extent of fouling, and it has the potential to be modified further so that it can be adopted in real process industries.
Subject Keywords
process monitoring
,
Soft-deposit
,
Cleaning
,
Fouling
URI
https://hdl.handle.net/11511/30371
Journal
Journal of Food Engineering
DOI
https://doi.org/10.1016/s0260-8774(03)00085-2
Collections
Graduate School of Natural and Applied Sciences, Article
Suggestions
OpenMETU
Core
Thermal contact conductance of nominaly flat surfaces
Yüncü, Hafit (2006-11-01)
The variation of thermal conductance of contact has been investigated as a function of apparent contact pressure experimentally. Experimental data has been obtained for steel, brass, copper and aluminum test pieces having different surface roughness over a wide range of contact pressures. Experimental results are compared with the theoretical predictions of an existing theory. Comparison revealed good agreement of trend with the experimental data, however, numerical values vary widely. Theory can predict th...
Experimental thermal performance characterization of flat grooved heat pipes
Alijani, Hossein; Çetin, Barbaros; Akkuş, Yiğit; Dursunkaya, Zafer (TAYLOR & FRANCIS INC, 530 WALNUT STREET, STE 850, PHILADELPHIA, PA 19106 USA, 2015-06-15)
The thermal characterization of aluminum flat grooved heat pipes is performed experimentally for different groove dimensions. Three heat pipes with groove widths of 0.2 mm, 0.4 mm, and 1.5 mm are used in the experiments. The effect of the amount of the working fluid is extensively studied for each groove width. The results reveal that, although all three succeed in dissipating the heat input through the phase change of the working fluid by continuous evaporation and condensation, the effectiveness of the he...
Energy analysis of a solar assisted absorption heat pump for floor heating system
Sarı, Özgür Gökmen; Yamalı, Cemil; Department of Mechanical Engineering (2004)
Solar assisted single-stage absorption heat pump (AHP) was used to supply energy to a floor-heating system by using the exergy methods. An existing duplex-house,in Ankara, with a heating load of 25.5 kW was analysed. Heating loads of the spaces in the building were calculated and a floor heating panel was modelled for each space leading to the capacity of the AHP before it was designed. Solar energy was delivered to the evaporator and high temperature heat input delivered to the genarator are met by auxilia...
Ternary nanocomposites of low density, high density and linear low density polyethylenes with the compatibilizers E-MA-GMA and E-BA-MAh
Işık Coşkunses, Fatma; Yılmazer, Ülkü; Department of Chemical Engineering (2011)
The effects of polyethylene, (PE), type, compatibilizer type and organoclay type on the morphology, rheological, thermal, and mechanical properties of ternary low density polyethylene (LDPE), high density polyethylene (HDPE), and linear low density polyethylene (LLDPE), matrix nanocomposites were investigated in this study. Ethylene – Methyl acrylate – Glycidyl methacrylate terpolymer (E-MAGMA) and Ethylene – Butyl acrylate- Maleic anhydrate terpolymer (E-BA-MAH) were used as the compatibilizers. The organo...
Vacuum-processed polyethylene as a dielectric for low operating voltage organic field effect transistors
Kanbur, Yasin; Irimia-Vladu, Mihai; Glowacki, Eric D.; Voss, Gundula; Baumgartner, Melanie; Schwabegger, Guenther; Leonat, Lucia; Ullah, Mujeeb; Sarica, Hizir; ERTEN ELA, ŞULE; Schwoediauer, Reinhard; Sitter, Helmut; Kucukyavuz, Zuhal; Bauer, Siegfried; Sariciftci, Niyazi Serdar (2012-05-01)
We report on the fabrication and performance of vacuum-processed organic field effect transistors utilizing evaporated low-density polyethylene (LD-PE) as a dielectric layer. With C-60 as the organic semiconductor, we demonstrate low operating voltage transistors with field effect mobilities in excess of 4 cm(2)/Vs. Devices with pentacene showed a mobility of 0.16 cm(2)/Vs. Devices using tyrian Purple as semiconductor show low-voltage ambipolar operation with equal electron and hole mobilities of similar to...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
X. D. Chen, D. X. Y. Li, S. X. Q. Lin, and N. Özkan, “On-line fouling/cleaning detection by measuring electric resistance-equipment development and application to milk fouling detection and chemical cleaning monitoring,”
Journal of Food Engineering
, pp. 181–189, 2004, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/30371.