Gas-Screen Slotted Quartz Tube Atomic Absorption Spectrometry: A Remedy for Reducing Interference Effects of Calcium and Chromium

2013-04-13
Gholami, M.
Yosefi, M. H.
Behkami, S.
Olyai, M. R. Talei Bavil
ARSLAN, YASİN
BAKIRDERE, Sezgin
Ataman, Osman Yavuz
A simple device for the reduction of nonspectral interferences in flame atomic absorption spectrometry is proposed. It has been reported that the use of a gas screen (GS) system together with a slotted quartz tube (SQT) enhances the residence time of analyte atoms in measurement zone even more than the SQT alone. This combination causes enhancement of sensitivity and improves the reproducibility of absorbance measurements. In addition, it protects the optical windows of the atomic absorption spectrometer. The operational mechanism of gas screen is simply applying two argon gas walls at both ends of SQT to provide an environment that is partly protected from air. This action enhances the sensitivity of measurement. In this study, interference effects of excess amounts of calcium and chromium on the measurements of Cd, Co, Cu, Pb, Mn, Ni, Se, and Zn were studied using flame AAS. The presence of both Ca and Cr cause higher absorbance values; it is suggested that this is due to formation of oxide species of Ca and Cr and as a result analyte oxide production is suppressed. Therefore, analyte free atom population and sensitivity are enhanced. This enhancement results in a positive error in measurements. For instance, presence of solely 8.0mgL1 of Cr or Ca for Pb as the analyte enhances the signals by 75% and 56%, respectively. When SQT or GS-SQT is used, this effect is significantly reduced.
ANALYTICAL LETTERS

Suggestions

SENSITIVITY ENHANCEMENT FOR SLOTTED QUARTZ TUBE FLAME ATOMIC ABSORPTION SPECTROMETRY USING A GAS SCREEN
Gholami, Mehrdad; Farjoud, Mohammad Javad; Sepehri, Masoud; Nazari, Ammar; Gholami, Majid; Behkami, Shima; Ataman, Osman Yavuz (2011-01-01)
Slotted Quartz Tube (SQT) is a simple device that provides a sensitivity enhancement of 2-5 times in Flame Atomic Absorption Spectrometry (FAAS) depending on the element. A Gas Screen-Slotted Quartz Tube (GS-SQT) was designed to further increase sensitivity. For this purpose, two slotted gas chambers were fixed on the left and right sides of a burner head and Ar gas was supplied into these chambers perpendicular to the light path to produce two thin layers of gas screen. It was observed that these Ar screen...
Sensitivity improvement for antimony determination by using in-situ atom trapping in a slotted quartz tube and flame atomic absorption spectrometry
TİTRETİR DURAN, SERAP; Sik, Ahmet Inanc; ARSLAN, YASİN; Ataman, Osman Yavuz (2012-11-01)
Significant improvement has been achieved for antimony determination using a slotted quartz tube (SQT) as an atom trap (AT) for in situ preconcentration and flame atomic absorption spectrometry (FAAS). The suggested technique consists of trapping analyte species during ordinary nebulization followed by releasing the collected analyte via introducing organic solvent. Procedures and analytical figures of merit have been presented for the techniques called FAAS. SQT-FAAS and finally SQT-AT-FMS with the relevan...
In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies
KILINÇ, ERSİN; BAKIRDERE, Sezgin; AYDIN, FIRAT; Ataman, Osman Yavuz (2013-11-01)
Analytical performances of metal coated slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) and slotted quartz tube in situ atom trapping flame atomic absorption spectrometry (SQT-AT-FAAS) systems were evaluated for determination of Bi. Non-volatile elements such as Mo, Zr, W and Ta were tried as coating materials. It was observed that W-coated SQT gave the best sensitivity for the determination of Bi for SQT-FAAS and SQT-AT-FMS. The parameters for W-coated SQT-FAAS and W-coated SQT-AT-FAAS ...
Gas mixing in conical spouted beds
Doğan, Neslin; Külah, Görkem; Department of Chemical Engineering (2020-12-28)
Conical spouted beds are relatively new generation gas-solid flow reactors used in various applications such as drying, catalytic polymerization, treatment of wastes, particle coating and chemical vapor deposition due to their advantages over cylindrical spouted beds. For complete characterization of conical spouted beds, determination of the local flow structure based on gas velocity and gas mixing is of paramount importance. There are limited studies on local gas behavior in conical spouted beds, especial...
Sensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse
Kilinc, Ersin; BAKIRDERE, Sezgin; AYDIN, FIRAT; Ataman, Osman Yavuz (2012-07-01)
Sensitivity of flame atomic absorption spectrometry (FAAS) for Bi determination was improved by slotted quartz tube (SQT) that was used also for atom trapping (AT). The trapped analyte was released by aspirating a small volume of organic solvent after a reasonable analyte collection time. Sensitivity was improved by 2.9 times by SQT-FAAS and 256 times by SQT-AT-FAAS with respect to FAAS. Optimum trapping period was found to be 6.0 min (36.0 mL of solution). Limit of detection (LOD) for SQT-AT-FAAS was found...
Citation Formats
M. Gholami et al., “Gas-Screen Slotted Quartz Tube Atomic Absorption Spectrometry: A Remedy for Reducing Interference Effects of Calcium and Chromium,” ANALYTICAL LETTERS, pp. 959–968, 2013, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/30704.