Flexural behavior of lightly and heavily reinforced steel fiber concrete beams

2015-11-15
Mertol, Halit Cenan
Baran, Eray
Bello, Hussain Jibril
Flexural behavior of lightly and heavily reinforced steel fiber concrete beams was investigated. The test series consisted of 20 singly reinforced beams having 180 x 250 x 3500 mm dimensions. The main parameters in the testing program were the type of concrete and the amount of longitudinal reinforcement. Ten different longitudinal reinforcement ratios (with a minimum of 0.2% and a maximum of 2.5%) covering the range from under-reinforced to over-reinforced beam behavior were used in the testing program. Two specimens were cast for each longitudinal reinforcement ratio, one specimen using conventional concrete (CC) and another specimen using steel fiber reinforced concrete (SFRC). Load-deflection behaviors were obtained and evaluated in terms of ultimate load, ultimate deflection, service stiffness, post-peak stiffness, and flexural toughness. The results indicate that the use of SFRC increases the ultimate load and service stiffness of the beams slightly compared to that of CC specimens. As reinforcement ratio increases, the ultimate deflection of SFRC specimens becomes significantly greater than that of CC specimens. For over-reinforced sections, the post-peak stiffness of the SFRC specimens is observed to be significantly lower than that of CC specimens. The flexural toughness of SFRC specimens is greater than that of CC specimens with the difference being significantly larger for over-reinforced sections. Experimental load-deflection relationships were also compared to the load-deflection curves obtained from sectional analyses based on strain compatibility and best fit stress-strain relationships for SFRC in tension and compression.
CONSTRUCTION AND BUILDING MATERIALS

Suggestions

Seismic assessment of reinforced concrete beam-to-column connections under reversed cyclic loading
Akın, Umut; Burak Bakır, Burcu; Department of Civil Engineering (2011)
Prior experimental research clearly reveals that the performance of reinforced concrete frame structures under earthquake loading is closely related to the behavior of beam-to-column connection regions. In order for a reinforced concrete building to have an adequate response under high lateral deformations, beam-to-column connections should be able to preserve their integrity. However, even today beam-to-column connections are assumed to be rigid or elastic, leading to an incorrect estimation of the structu...
Seismic response assessment of a stiff structure
Kazaz, I; Yakut, Ahmet; Gulkan, P (Wiley, 2006-05-01)
Seismic response of a lightly reinforced stiff shear-wall structure subjected to ground motions grouped as near- or far-field according to their distance to causative faults is investigated. A model structure that had earlier been studied both experimentally and analytically in the context of a co-ordinated research project is re-examined. The structure is a five-storey lightly reinforced shear-wall model subjected analytically to 55 ground motion records from firm soil sites. Several response parameters ar...
Seismic behavior of autoclaved aerated concrete reinforced vertical panel buildings
Gökmen, Furkan; Binici, Barış; Department of Civil Engineering (2017)
In this study, the seismic behavior of Autoclaved Aerated Concrete (AAC) reinforced panel walls and buildings was investigated. The structural members were investigated under cyclic lateral loading and axial load and the results were compared with the previous tests. The main objective of this study was to provide recommendations for nonlinear analysis of the reinforced AAC panel walls and buildings. OpenSees plat-form was chosen as the computational platform. The walls were modeled with fiber sections. The...
Structural Applications of a Reinforced Concrete Beam-Column-Slab Connection Model for Earthquake Loading
Burak Bakır, Burcu (null; 2008-10-12)
Analytical studies to evaluate the seismic response of reinforced concrete moment resisting frame structures, with and without joint deformations, demonstrated that the predicted inelastic behavior was not accurate when the joint region was assumed to be rigid. One of the main purposes of the research program was to develop a joint model that accounts for deterioration of shear strength and stiffness within the connection region and concentrated rotation due to rebar slip. The experimental data on joint dis...
Use of steel fiber reinforced mortar for seismic strengthening
Sevil, Tugce; BARAN, MEHMET; Bilir, Turhan; Canbay, Erdem (2011-02-01)
The objective of this research was to develop an economical, structurally effective, and practically applicable steel fiber reinforced mortar (SFRM) which could be applied onto the hollow brick infills of a reinforced concrete (RC) structure. Masonry walls were almost converted into strong and rigid infills with the application of SFRM. Two different mix proportions were produced with the composition of Portland cement, fine aggregate, water, and plasticizer or bonding agent as the chemical admixture. Tests...
Citation Formats
H. C. Mertol, E. Baran, and H. J. Bello, “Flexural behavior of lightly and heavily reinforced steel fiber concrete beams,” CONSTRUCTION AND BUILDING MATERIALS, pp. 185–193, 2015, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/35784.