Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS)

Download
2018-01-25
Gomez-Rios, German Augusto
Tascon, Marcos
Reyes-Garces, Nathaly
Boyacı, Ezel
Poole, Justen James
Pawliszyn, Janusz
Coated Blade Spray (CBS) is a technology that efficiently integrates sample preparation and direct coupling to mass spectrometry (MS) on a single device. In this article, we present CBS-tandem mass spectrometry (CBS-MS/MS) as a novel tool for the rapid and simultaneous determination of four commonly used immunosuppressive drugs (ISDs) in whole blood: tacrolimus (TAC) and cyclosporine-A (CycA), which are calcineurin inhibitors; and sirolimus (SIR) and everolimus (EVR), which are both mTOR (mechanistic target of rapamycin) inhibitors. Given that CBS extracts via free concentration, analytes that are largely bound to plasma proteins or red blood cells provide considerably lower extraction recovery rates. Therefore, we defy the solventless philosophy of SPME-based techniques, like CBS, by performing the analyte-enrichment step via direct immersion in a solvent-modified matrix. The assay was linear within the evaluated range of concentrations (between 1 and 100 ng/mL for EVR/SIR/TAC and 10-1000 ng/mL for CycA), and the limits of quantification were determined to be 10 ng/mL for CycA and 1 ng/mL for EVR/SIR/TAC. Good accuracy (87-119%) and linearity (r(2) >= 0.99) were attained over the evaluated range for all ISDs. Interassay imprecision (CV) determined from incurred sample reanalysis was <= 10% for all ISDs. Our method was validated using Liquichek (TM) whole blood immunosuppressant quality control (QC) standards purchased from Bio-Rad. Concentrations determined by CBS-MS/MS were inside the range specified by Bio-Rad and within 15% of the expected mean value for all ISDs at all QC levels. Furthermore, the effect of different hematocrit levels (20,45, and 70%) in the entire calibration range was carefully studied. No statistical differences (RSD <= 7%) in the calibration curve slopes of ISDs in blood were observed. CBS offers a simpler workflow than that of traditional methods; it eliminates the need for chromatographic separation and provides a clean extract that allows for long-term MS instrumental operation with minimal maintenance. Additionally, because CBS integrates all analytical steps into one device, it eliminates the risk of instrumental carry-over and can be used as a low-cost disposable device for sample preparation and analysis. Fully-automated sample preparation simplifies the method and allows for total analysis times as short as 3 min with turn-around times of less than 90 min.
ANALYTICA CHIMICA ACTA

Suggestions

Improving the laser damage resistance of oxide thin films and multilayers via tailoring ion beam sputtering parameters
Cosar, M. B.; Ozhan, A. E. S.; Aydogdu, G. H. (2015-05-01)
Ion beam sputtering is one of the widely used methods for manufacturing laser optical components due to its advantages such as uniformity, reproducibility, suitability for multilayer coatings and growth of dielectric materials with high packing densities. In this study, single Ta2O5 layers and Ta2O5/SiO2 heterostructures were deposited on optical quality glass substrates by dual ion beam sputtering. We focused on the effect of deposition conditions like substrate cleaning, assistance by 12 cm diameter ion b...
Direct insertion mass spectrometric analysis of thermal degradation of poly(2-alkyl-2-oxazoline)
Atilkan, Nurcan; Nur, Yusuf; Hacaloğlu, Jale; Schlaad, Helmut (2012-05-14)
Direct pyrolysis mass spectrometry is applied to investigate the thermal behavior of poly(2-isopropyl-2-oxazoline) (PIPOX, a thermoresponsive polymer) and poly[2-(3-butenyl)-2-oxazoline] (PBOX, a clickable polymer). It is found that the thermal degradation of PIPOX is started by a loss of side chains. At slightly higher temperatures the degradation of the polymer backbone occurs by random chain scission processes. In the case of PBOX, vinyl polymerization of the side chains produces chains with variable the...
Direct pyrolysis mass spectrometry studies on thermal degradation characteristics of poly(phenylene vinylene) with well-defined PSt side chains
Nur, Y.; Çolak, Demet; Cianga, I.; Yagci, Y.; Hacaloğlu, Jale (2008-10-01)
Thermal degradation characteristics of a new macromonomer polystyrene with central 4,4'-dicarbaldehyde terphenyl moieties and poly(phenylene vinylene) with well-defined polystyrene (PPV/PSt) as lateral substituents were investigated via direct pyrolysis mass spectrometry. A slight increase in thermal stability of PSt was detected for (PPV/PSt) and attributed to higher thermal stability of PPV backbone. It was almost impossible to differentiate products due to the decomposition of PPV backbone from those pro...
Active vibration suppression of a smart beam via self sensing piezoelectric actuator
Uğur, Arıdoğan; Şahin, Melin; Yaman, Yavuz; Volkan, Nalbantoğlu (null; 2009-08-17)
In this paper, an active vibration suppression of a smart beam using self-sensing piezoelectric actuator is presented. The smart beam is composed of a cantilever aluminium beam with four surface-bonded piezoelectric patches symmetrically located both side of the beam. Piezoelectric materials can transform mechanical deformation to electric signal and vice versa. This property of piezoelectric materials enables them to be used as an actuator and a sensor. In self-sensing actuator configuration, the piezoelec...
Characterization of novel materials for fused filament fabrication
AL-DUAIS, ABDULLAH ABDULRAHMAN NAJI; Özerinç, Sezer; Kazanç Özerinç, Feyza; Department of Mechanical Engineering (2021-6-24)
Fused filament fabrication (FFF) is a polymer additive manufacturing technology that is suitable for a wide range of applications due to its low cost and ease of use. This thesis investigated two types of novel materials for FFF use. First, a foaming PLA filament is considered and the mechanical properties of 3D printed specimens using this filament is characterized. The results show that the strength, modulus and density of the foaming PLA can be tuned over a wide range of values by varying FFF process par...
Citation Formats
G. A. Gomez-Rios, M. Tascon, N. Reyes-Garces, E. Boyacı, J. J. Poole, and J. Pawliszyn, “Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS),” ANALYTICA CHIMICA ACTA, pp. 69–75, 2018, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/41819.