Lateral load testing of an existing two story masonry building up to near collapse

2017-08-01
Laboratory testing, although necessary to understand failure mechanisms of individual masonry walls, spandrels or small scale building models, cannot fully mimic the real system behavior of masonry structures. In order to observe the performance of an existing two story masonry structure, cyclic lateral load testing up to near collapse was conducted. The test building was sliced approximately in the middle through the reinforced concrete slabs of both stories and one side was strengthened with the objective of obtaining a strong reaction wall. The other side of the structure was taken as the test structure with a floor plan of approximately 10 m x 10 m. Hydraulic actuators attached at the slabs of both stories were employed to impose one way cyclic displacement excursions. Flexural and shear deformations on a number of walls were measured and crack propagations were monitored. The structure was tested up to a lateral strength drop of approximately 20 % from the ultimate load, which occurred at a drift ratio of about 0.60 %. The failure of the walls in the building, which were mostly failed in a diagonal tension mode, was concentrated on the first story. Results of this valuable test provide important data on the performance of an actual masonry building and were employed to assess the applicability of various stiffness and strength and simplified load-deformation models in the literature.
BULLETIN OF EARTHQUAKE ENGINEERING

Suggestions

Seismic strengthening of a mid-rise reinforced concrete frame using CFRPs: an application from real life
Tan, Mustafa Tümer; Özcebe, Güney; Department of Civil Engineering (2009)
FRP retrofitting allows the utilization of brick infill walls as lateral load resisting elements. This practical retrofit scheme is a strong alternative to strengthen low to mid-rise deficient reinforced concrete (RC) structures in Turkey. The advantages of the FRP applications, to name a few, are the speed of construction and elimination of the need for building evacuation during construction. In this retrofit scheme, infill walls are adopted to the existing frame system by using FRP tension ties anchored ...
Experimental evaluation of the in-plane behaviour of masonry wall infilled RC frames
Suzuki, Tomomi; Choi, Ho; Sanada, Yasushi; Nakano, Yoshiaki; Matsukawa, Kazuto; Paul, Devjyoti; Gulkan, Polat; Binici, Barış (2017-10-01)
This study focuses on the in-plane behaviour of unreinforced masonry (URM) infill walls installed in reinforced concrete (RC) frames. Five 1/4-scale model frames were designed based on a prototype RC building with URM infill walls in Turkey. The experimental parameters were the layout of the URM infill (its presence or absence), number of spans (single or double), number of stories (single or double), and stacking pattern of the URM infill (horizontal or vertical). Static cyclic loading tests were conducted...
Vulnerability assessment of reinforced concrete moment resisting frame buildings
Erduran, Emrah; Yakut, Ahmet (2007-04-01)
A detailed seismic performance assessment procedure has been developed for reinforced concrete (RC) frame buildings with masonry infill walls. The procedure is based on member damage functions, in terms of interstory drift ratios. These functions are developed for the primary components, namely, columns, beams, and infill walls. For developing these functions, analytical investigations to determine the influence of several parameters on the damageability of components were combined with experimental data. A...
Modelling of strengthened hollow brick infills
BARAN, MEHMET; Ozcelik, Ramazan; Sevil, Tugce; Canbay, Erdem (2013-02-01)
Strengthening the existing hollow brick infill walls by bonding high-strength precast concrete panels or applying steel fibre reinforced mortar was found to be an occupant-friendly seismic retrofitting technique for the buildings in use with deficient reinforced concrete structural systems. Both techniques convert the existing non-structural hollow brick infill walls into load-carrying structural members. To verify the effectiveness of the techniques, 20 reinforced concrete frames with hollow brick infill w...
Seismic Strengthening with Precast Concrete Panels - Theoretical Approach
Baran, Mehmet; Canbay, Erdem; Tankut, Tugrul (2010-01-01)
An economical, structurally effective and practically applicable seismic retrofitting technique has been developed on the basis of the principle of strengthening the existing hollow brick infill walls by using high strength precast concrete panels. The technique would not require evacuation of the building and would be applicable without causing much disturbance to the occupant. For this purpose, a total of eighteen reinforced concrete frames with hollow brick infill walls were tested under reversed cyclic ...
Citation Formats
A. Aldemir, B. Binici, E. Canbay, and A. Yakut, “Lateral load testing of an existing two story masonry building up to near collapse,” BULLETIN OF EARTHQUAKE ENGINEERING, pp. 3365–3383, 2017, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/42340.