Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
An Uncooled Microbolometer Focal Plane Array Using Heating Based Resistance Nonuniformity Compensation
Date
2012-04-27
Author
Tepegoz, Murat
Oguz, Alp
Toprak, Alperen
Senveli, S. Ufuk
Canga, Eren
Tanrikulu, M. Yusuf
Akın, Tayfun
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
230
views
0
downloads
Cite This
This paper presents the performance evaluation of a unique method called heating based resistance nonuniformity compensation (HB-RNUC). The HB-RNUC method utilizes a configurable bias heating duration for each pixel in order to minimize the readout integrated circuit (ROIC) output voltage distribution range. The outputs of each individual pixel in a resistive type microbolometer differ from each other by a certain amount due to the resistance non-uniformity throughout the focal plane array (FPA), which is an inevitable result of the microfabrication process. This output distribution consumes a considerable portion of the available voltage headroom of the ROIC unless compensated properly. The conventional compensation method is using on-chip DACs to apply specific bias voltages to each pixel such that the output distribution is confined around a certain point. However, on-chip DACs typically occupy large silicon area, increase the output noise, and consume high power. The HB-RNUC method proposes modifying the resistances of the pixels instead of the bias voltages, and this task can be accomplished by very simple circuit blocks. The simplicity of the required blocks allows utilizing a low power, low noise, and high resolution resistance nonuniformity compensation operation. A 9-bit HB-RNUC structure has been designed, fabricated, and tested on a 384x288 microbolometer FPA ROIC on which 35 mu m pixel size detectors are monolithically implemented, in order to evaluate its performance. The compensation operation reduces the standard deviation of the ROIC output distribution from 470 mV to 9 mV under the same readout gain and bias settings. The analog heating channels of the HB-RNUC block dissipate around 4.1 mW electrical power in this condition, and the increase in the output noise due to these blocks is lower than 10%.
Subject Keywords
Microbolometer readout circuit
,
Resistance nonuniformity compensation
URI
https://hdl.handle.net/11511/46163
DOI
https://doi.org/10.1117/12.964525
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
A low power readout circuit approach for uncooled resistive microbolometer FPAs
Tepegoz, Murat; Toprak, Alperen; Akın, Tayfun (2008-03-20)
This paper presents a new, low power readout circuit approach for uncooled resistive microbolometer FPAs. The readout circuits of the microbolometer detectors contain parallel readout channels whose outputs are driven and multiplexed on large bus capacitances in order to form the output of the readout circuit. High number of opamps used in the readout channel array and large output capacitances that these opamps should drive necessitates the use of high output current capacity structures, which results in l...
An electrostatic parylene microvalve for controlling in plane flow
Yıldırım, Ender; Külah, Haluk (null; 2009-11-01)
This paper presents analysis, implementation, and testing of a new and simple electrostatic microvalve for in-plane flow manipulation. The reported microvalve implements electrostatic pull-in of a parylene diaphragm located parallel to the flow.
A Two-Stage Digital-to-Analog Converter for Bias Correction in Uncooled Microbolometer Arrays
Toprak, Alperen; Tepegoz, Murat; Akın, Tayfun (2011-04-29)
This paper introduces a detector biasing scheme proper for resistive microbolometer type uncooled thermal detector focal plane arrays (FPAs). The proposed scheme utilizes a 2-stage digital-to-analog converter (DAC) architecture where the first DAC stage generates the voltage interval that covers the bias voltage range of the overall FPA, while the second stage generates the high resolution analog voltages that are used to apply pixel-specific bias voltages. The second DAC stage output includes a resistive l...
Dynamic resistance nonuniformity compensation circuit for uncooled microbolometer detector arrays
Yildirim, Omer Ozgur; Akın, Tayfun (2006-04-21)
This paper presents a new approach for compensating resistance nonuniformity of uncooled microbolometers by adjusting the bias currents of both detector and reference pixels. Contrary to conventional nonuniformity compensation circuits, this approach eliminates the need for digital-to-analog converters (DACs), which usually occupy a large area, dissipate high power, and require complicated external circuitry with high frequency data transfer to the microbolometer chip. The proposed circuit uses a feedback s...
A Thermal Conductance Optimization and Measurement Approach for Uncooled Microbolometers
Senveli, S. Ufuk; Tanrikulu, M. Yusuf; Akın, Tayfun (2011-04-29)
This paper introduces an optimization approach of thermal conductance for single level uncooled microbolometer detectors. An efficient detector design is required due to the limited availability of silicon area per pixel, i.e., the pixel pitch, and due to the capabilities of the fabrication line. The trade-offs between physical parameters are studied to attain the best performance, including the thermal conductance, the thermal time constant, the effective temperature coefficient of resistance (TCR), and th...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. Tepegoz et al., “An Uncooled Microbolometer Focal Plane Array Using Heating Based Resistance Nonuniformity Compensation,” 2012, vol. 8353, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/46163.